Vivotek IP7251 manual CCD Settings

Page 38

VIVOTEK - A Leading Provider of Multimedia Communication Solutions

CCD Settings

Click CCD settings to open the CCD Settings page. In this page, you can set the exposure level, enable AGC, enable BLC functions. night mode, and IR cut filter.

Exposure level:

You can manually set up the Exposure level, which ranges from 1 to 8. The default value is 4.

Enable AGC (Auto Gain Control):

You can manually set up the AGC level (MAX or Normal).

Enable BLC (Back Light Compensation)

Enable it when the object is too dark or too bright to recognize. It allows the camera to adjust to the best light conditions in any environment and automatically give the necessary light compensation.

Switch to B/W in night mode:

Select it to enable the Network Camera to automatically switch to B/W in night mode.

IR cut filter:

With a removable IR-cut filter and built-in IR illuminators, up to 15m, this Network Camera can automatically remove the filter and turn on the IR illuminators during the nighttime to accept IR illumination for low light sensitivity.

■ Auto

The Network Camera automatically removes the filter by judging the level of ambient light.

■ Schedule mode

The Network Camera switches between day mode and night mode based on specified schedule. Enter the starting time and ending time for the day mode. Note that the time format is [hh:mm] and is expressed in 24-hour clock time. By default, the starting time and ending time of day mode are set to 07:00 and 18:00.

■ Day mode

In day mode, the Network Camera switches on the IR cut filter at all times to block the infrared light from reaching the sensor so that the colors will not be distorted.

38 - User's Manual

Image 38
Contents Page Table of Contents Package contents Read before usePhysical description LensDI/DO Diagram Hardware installation Hardware ResetSetup the Network Camera over the Internet Network deploymentInternet connection with static IP Set up the Network Camera through Power over Ethernet PoE Software installation RoHSAccessing the Network Camera Using web browsersPage Using Rtsp players Using 3GPP-compatible mobile devices MPEG-4Using Vivotek recording software Main Live Video Window Video title Title and time Client Settings MP4 Saving Options System Time SystemSystem DI and do Add User Root PasswordSecurity Manage UserNetwork Network TypePPPoE Point-to-point over Ethernet Page Http Two way audio FTP Rtsp Streaming Page Ddns Dynamic domain name service DdnsCustomSafe100 Delete allowed list / Delete denied list Access listAllowed list / Denied list Video settings Audio and videoImage Settings Privacy mask CCD Settings Page Audio settings To enable motion detection, follow the steps below Motion detectionPercentage = 30% RS485 Settings Camera controlPreset Position Custom CommandNetwork Camera Media Settings ApplicationSnapshot20080104100341 Server Settings Page Page Event Settings Page Recording Settings RecordingPage Video content analysis Page Current Log System logRemote Log View parameters Restore MaintenanceReboot Upload / Export Daylight Saving Time Configuration File Upgrade Firmware Page URL Commands of the Network Camera AppendixGet server parameter values General CGI URL syntax and parametersSecurity level Parameter pair Update Set server parameter valuesAvailable parameters on the server Valid Values DescriptionName Value Default Security Vegas, SanFrancisco, Vancouver Page None Name Value Default Security Description Name Value Default Name 5060 SIP port Capability.protocol.sip=1 External camera VGA Cmos PAL CCD Get/set Brightness Adjust brightness of image TZO Get/set Boolean Level To control Uart Null Function Bit 3 = Support tilt operation Output Parameter Value Iva indicates Intelligent Video Parameter Value Default Security Description Httpusername String64 Indicate the prefix Max size for one file in Kbytes Drive the digital output Query status of the digital input Query status of the digital output Capture single snapshotAccount management QualitySystem logs Upgrade firmware Post dataRecall capability.ptzenabled=1 System Information Value DescriptionPreset Locations capability.ptzenabled=1 IP filteringUart Http tunnel channel capability.nuart0 End parameters are specified, it will try to removeGet SDP of Streamings Open the network streamingsPage Technical Specifications SpecificationsTechnology License Notice Electromagnetic Compatibility EMC