JVC TK-C1481  Connecting the control signal cable,  Setting the switches , When connecting

Page 13

Connecting the control signal cable

(Use a twisted-pair cable for connection.  Page 17.)

Camera 1 control signal connection terminals

TX+ A

TX B

RX+ C

RX D

Camera 2 control signal connection terminals

TX+ A

TX B

RX+ C

RX D

RM-P2580

A RX +

BRX

CTX +

DTX

Connect:

Camera TX+ to RM-P2580 RX+ Camera TX– to RM-P2580 RX– Camera RX+ to RM-P2580 TX+ Camera RX– to RM-P2580 TX–

The A B C D marks indicated on both the camera terminals and the RM-P2580 termi- nals facilitate correct connections. Connect the terminals with identical marks.

Setting the switches (

 

 

 

 

EXT TERM-OFF

 

 

 

 

INT/GL

SET

CAMERA

 

 

DUPLEX

AWC

SETUP

EXT TERM-OFF

ON

RX TERM-OFF

MENU

 

DUPLEX

SIMPLEX

 

INT/GL

LL

 

 

 

RX TERM-OFF

ON

 

 

 

NOT USED

 

NOT USED

 

 

 

 

 

 

 

VIDEO

IRIS

 

 

 

DC

 

Page 10)

Select the synchronization method of the camera image.

Set the switch on all cameras to LL (Line Lock) and match with the V. PHASE.

( Page 26.)

ON

LLSet this switch to the DUPLEX

SIMPLEX * If the setting is changed, be absolutely sure to

ON

switch on the power again.

Set this switch to ON (signal termination ON) only on the camera placed at the end of the control signal cable.

Set to OFF on all other cameras.

Setting on the MENU screen ( Page 33)

* If the setting is changed, escape from the menu screen once, and definitely switch on the power again.

C OMMUN I C A T I O N

 

S T YL E

M . DROP

MACH I NE I D

1

Set to M.DROP

Set to M.DROP when the RM-P2580 is used as a remote control unit. When controlling from another machine, make sure that it matches the communication system used.

MACHINE ID setting switches

Set this item to match the RM-P2580 VIDEO INPUT terminal number for each camera.

When connecting

Turn OFF the power supply to all equipment to be used before making connections.

Carefully read the Instructions for each piece of equipment to be used before making connections.

For the appropriate connection cables and the length of these, carefully read “Connections on the back” on page 16.

The control signal cable cannot be used for loop connection.

E-13

Image 13
Contents TK-C1480 TK-C1481 Important Safeguards Page Safety Precautions Contents Memo Features Reference page or item Operating Precautions Lens mount Controls, Connectors and IndicatorsCamera-mounting screw hole 1/4 inch Rotation-preventive holeCover VIDEO/DC Iris Selector SwitchIris Iris Terminal Menu Menu ButtonDUPLEX, Simplex Selector Switch for Transmission System 15 INT/GL, LL Selector Switch for Synchronizing System17 RX.TERM-ON/OFF RX SignalTerminal ON/OFF Switch 13 , , , Up-and-down, left-and- right ButtonVideo OUT Video signal output connector 22 Y/C OUT Y/C output connectorPower Power indicator lamp Power cable TK-C1481EG System with up to 8 cameras RM-P2580 System Setting the switches   Connecting the control signal cable Setting on the Menu screen  When connectingSetting the switches ProceduresThis is the connected example of the TK-C1480U or TK-C1480E TK-C1481EG DC Iris Video Iris Mounting the lensVideo GNDConnections on the back  Power supplyTK-C1481EG AC230V  Genlock connection  Control signal cablesFall Prevention Mounting the cameraSpecified screw M3 ⋅ 6 mm Installation of camera Level adjustment Lens adjustmentDoes not operate  Back focus adjustment Back focus adjustmentLens Focus Adjustment Mode With a fixed-focus lensError message display Auto white balance control adjustmentMenu screen is displayed Setting the menuSelected sub-menu screen is displayed Change of the set value displays a change mark ∗Word Colour is displayed as Color on the TK-C1480U Flow of menu screenTK-C1480U does not display these characters ALC Settings Screen Sync Adjust ScreenFunctions and set values Initial value ExDR ShutterSpeed Memo Motion PriorityBLC OFFVideo Adjust Screen Motion Detect Screen Mode Select ScreenArea Edit Alarm TimeCommunication Screen Factory Settings ScreenBLC Editting Screen Manual Adjustment of White Balance Screen returns to Mode Select Camera Title SettingThen, the Camera Title screen is brought up Selected character is displayed flashing on and offSetting screen is brought up Setting the Motion Detect FunctionSelect the item Area Edit on Motion Detect screenSpecifications Installing the ferrite coreDimensions Unit mm Video OUT Composite video signal 1 V p-p, 75Ω BNCOUT Colour Video Camera