CONNECTION/INSTALLATION
Connections on the back
Power supply
TK-C1480U and TK-C1480E (DC 12 V or 24 V)
| + | - |
|
|
|
|
|
| 1 | 2 | ISOLATEDPOWER ONLY |
|
|
|
|
DC12V | AC24V | CLASS2 ONLY(U TYPE) | (E TYPE) |
|
|
| |
|
|
|
| TX+ TX- RX+ RX- AUX GND | |||
|
|
|
| A | B | C | D |
| Y/C OUT |
SYNC IN | VIDEO OUT |
| SEE INST- |
POWER | RUCTION |
MANUAL |
Connect the DC 12 V or the AC 24 V power supply to the DC 12V/AC 24V terminals. To prevent connection errors or a cable disconnection, we recommend the use of lug plates for the connections.
The following table shows the connection distances and connection cables provided that
Maximum extension | 100 m | 260 m | 410 m | 500 m |
(reference) |
|
|
|
|
Conductor | 1.0∅mm | 1.6∅mm | 2.0∅mm | 2.6∅mm |
diameter | and more | and more | and more | and more |
|
|
|
|
|
MEMO
•If thin cables are used (i.e. with a high resistance), a significant voltage drop will occur when the unit is at its maximum power consumption. Either use a thick cable to restrict the voltage drop at the camera side to below 10%, or place the power supply near to the camera. If voltage drop occurs during operation, the performance will be unstable.
•Attach the cable conductors so that they do not come into contact with the drop prevention wires.
•Do not allow input from both a DC 12 V and AC 24 V power supply at the same time.
•When using a DC 12 V power supply, ensure that the polarities of the cable are correct.
•The AC 24 V power supply should conform to the following:
TK-C1481EG (AC230V)
| Y/C OUT |
SYNC IN | VIDEO OUT |
| SEE INST- |
| RUCTION |
POWER | MANUAL |
Power cable connect to the commercial AC230V outlet
CAUTION:
When you use this camera, the