CONNECTION/INSTALLATION
Lens adjustment
Connect the camera according to the connection method, turn it on, display an image on the monitor, and check the image. The camera has been
LEVEL adjustment
L H | LEVEL |
Av Pk | ALC |
ALC adjustment
(Does not operate.)
MEMO
Note that the lens cannot make ALC adjust- ments. Make ALC adjustments using the item AVERAGE: PEAK on the menu.
( Page 26)
• LEVEL adjustment
Monitor screen | LEVEL turning direction |
|
|
Too bright | Counterclockwise (Toward L) |
|
|
Too dark | Clockwise (Toward H) |
|
|
MEMO
•If the sensitivity adjustment LEVEL is turned excessively to L, the sensitivity in- creases because of the AGC function of the camera, and the image looks grainy.
•If the video iris lens is set to too low a level, malfunction such as the hunting phenom- enon, in which the iris opens or closes unintentionally, may occur.
In such a case, first set LEVEL potentiom- eter on the lens to the H (iris open) posi- tion then adjust it to the optimum level.