5. Menu screen settings (continued)
SYSTEM SETTING screen |
MENU (QUICK) screen
[ ] indicates the factory setting |
|
|
| |
Item | Set Value |
|
| Contents |
AE DISPLAY | [OFF] | Used to set whether the ALC, EEI and IRIS values are | ||
| ON | displayed on the analog output screen. | ||
|
| OFF: | No | |
|
| ON: | ||
FRZ DISPLAY | [ON] | Used to set whether the “FREEZE” indicator is shown on | ||
| OFF | the screen at the time of trigger input. | ||
|
| ON: | Displayed | |
|
| OFF: | Not displayed | |
FRZ CANCEL | [MANUAL] | Sets the method for canceling the FREEZE when the | ||
| AUTO (1s) | monitor screen is in FREEZE condition when connection | ||
| AUTO (3s) | is made through digital output. | ||
| AUTO (5s) | MANUAL | : | Cancelled by trigger input. |
| OFF | AUTO(1s) | : | Cancelled after 1 second. |
|
| AUTO(3s) | : | Cancelled after 3 seconds. |
|
| AUTO(5s) | : | Cancelled after 5 seconds. |
|
| OFF | : | Not cancelled. |
*When set to “AUTO” or “OFF”, the displayed screen can be updated by trigger input during the FREEZE condi- tion.
TEST PATTERN | [BAR] | Sets the test pattern type output when the function set- | ||
| RAMP | ting switch No.1 <TEST PATTERN> is set to “ON”. | ||
| IMPULSE | BAR | : | “BAR” pattern is output. |
|
| RAMP | : | “RAMP” pattern is output. |
|
| IMPULSE : | “IMPULSE” pattern is output. | |
LEVEL | [0.7V] | Sets the level of the color signal bar output from the KY- | ||
When “BAR”/ | 0.57V | 1030’s [ANALOG OUT] connector. | ||
“IMPULSE” |
| 0.7V: | 0.7V test signal is output | |
is selected |
| 0.57V: | 0.57V test signal is output | |
MENU RESET |
| Resets all the set values of menus to the initial values. | ||
|
| page E43, Resetting menu settings |
[ ] indicates the factory setting | |
Item | Set Value |
AE LEVEL | |
| |
| • |
| [0] |
| • |
| • |
| 126 |
| 127 |
IRIS LEVEL | 0 |
| 1 |
| • |
| • |
| [255] |
SHUTTER | [STEP] |
| V.SCAN |
| RANDOM |
| EEI |
| OFF |
SPEED | 4s |
When | 2s |
“STEP” is | 1s |
selected | 1/2s |
| 1/4s |
| [1/8s] |
| 1/15s |
| 1/30s |
| 1/60s |
| 1/125s |
| 1/250s |
| 1/500s |
| 1/1000s |
| 1/2000s |
|
| Contents |
Used to adjust the video level when using auto iris, ALC | ||
and EEI. |
|
|
Increase the number : | raise the level | |
Decrease the number : | lower the level | |
MEMO |
|
|
not work. |
|
|
Used to set the iris level when the IRIS MODE is set to | ||
“MANUAL”. |
|
|
Increase the number : | open iris | |
Decrease the number : | close iris | |
Used to switch the shutter mode. | ||
STEP: | The shutter speed can be changed with the | |
V. SCAN: | [SPEED] item. | |
The shutter speed can be changed with the | ||
| [SPEED] item. | |
| Enables more detailed setting than [STEP]. | |
RANDOM: Used to synchronize the CCD accumulation | ||
| timing with the trigger input. | |
| The shutter speed can be changed with the | |
EEI: | [SPEED] item. | |
Used to automatically change the shutter | ||
| speed in accordance with the brightness of the | |
OFF: | subject. |
|
Fixed at 1/7.5 s. | ||
The shutter speed can be changed when SHUTTER is | ||
set to “STEP”, “V.SCAN” or “RANDOM”. |
E40 | E41 |