JVC KY-F1030 Pin configurations of connectors, Lens terminal Metal 12-pin, female, 15-pin, female

Page 9

1. Introduction (continued)

Pin configurations of connectors

DC IN terminal (Mini DIN 8-pin, female)

 

7

 

 

8

 

 

 

6

5

3

24

1

Pin no.

Signal name

1NC

2GND

3NC

4NC

5GND

612V

7NC

812V

LENS terminal (Metal 12-pin, female)

9

10

1

8

2

7

3

6

 

4

12

5

11

 

 

Pin no.

Signal name

1

NC

2

NC

3

GND

4

NC

5

IRIS CONTROL

6

12V DC 400mA max.

REMOTE terminal (Metal 10-pin, female)

8

1

7

2

10

9

 

6

3

 

5

4

Pin no.

 

Signal name

1

A. WHITE L active

2

TRG IN L active

3

WEN L active 3.3V(p-p)

4FLASH

5NC

6RS-SDI

7RS-SDO

8GND

912V

10

OPERATION

CAUTION

Consult your JVC dealer concerning the re- mote terminal connection.

Remote cable must use shielded cable. Outer shield of remote cable must to connect 10-pin connector outer metal shell.

Do not input the external trigger during the

first 5 seconds after the power is turned ON.

Terminal

 

I/O

Conditions

name

 

 

 

 

 

 

 

2 TRG IN

IN

• Contact point

 

3.3V CMOS

recommended

 

Schmidt Trigger

• Maximum rated

 

Pull-up to 3.3V at

voltage: 5.3V

 

 

4.7k

• H level: 2.4 ~ 5.0V

 

 

 

• L level: 0 ~ 0.5V

 

 

 

• Pulse width:

 

 

 

130 s or higher

3 WEN

OUT

 

ANALOG OUTPUT terminal (D-sub

15-pin, female)

 

 

5

1

 

10

6

 

15

11

Pin no.

 

Signal name

1

R OUT 700mV(p-p), 75

2

G OUT 700mV(p-p), 75

3

B OUT 700mV(p-p), 75

4NC

5NC

6R GND

7G GND

8B GND

9WEN

10 GND

11 GND

12 NC

13 Hs (3.3V(p-p) negative polarity)

14 Vs (3.3V(p-p) negative polarity)

15

NC

 

CAUTION

 

Do not connect directly to monitor for use with

personal computers.

 

IEEE 1394 connector

 

 

6

 

 

 

5

 

 

 

 

 

4

 

 

 

3

 

 

 

 

 

2

 

 

 

1

 

 

 

 

MD CONTROL (Metal 12-pin, female)

1

10

9

2

8

3

7

46

11 5 12

Pin no.

Signal name

1FOCUS CONT SELECT

2ZOOM CONT SELECT

3GND

4 ~ 5

NC

6+12 V

7NC

8FOCUS CTL

9ZOOM CTL

10 ~ 12

NC

7

IRIS POSITION

8

IRIS AUTO /MANU

9 to 12

NC

CAUTION

Use device whose current consumption is max.

400 mA or less.

E12

 

 

• 3.3V (p-p)

 

 

negative polarity

 

 

 

 

4 FLASH

OUT

• Maximum rated

 

• Open collector

current: 150mA

 

 

• Maximum rated

 

 

voltage: 12V

Pin no.

Signal name

1VP (Current)

2VG (GND)

3TPB –

4TPB +

5TPA –

6TPA +

E13

Image 9
Contents This instruction book is made from 100% recycled paper Illustration with optional lens attachmentSerious damage to the appliance Important SafeguardsJVC Professional Products Italia S.p.A These instructions are for KY-F1030U Table of Contents Features Accessories and attachmentsIntroduction Front and bottom Part names and their functionsRear Side switch panel section insideIeee 1394 connector MD Control Metal 12-pin, female Pin configurations of connectorsLens terminal Metal 12-pin, female Analog Output terminal D-subConnecting through analog output connector Connecting through digital output connectorBefore shooting AC adapterMounting the lens Combining with a presentation systemConnecting the IEEE1394 Cable Connecting powerMounting the camera Mounting methodSettings and adjustments for shooting Lens settingsAuto Temp the text will be displayed in purple when se White balance adjustmentError Over Light excessive light Lected, then press the SET buttonFocus adjustment Shooting a computer monitor screen Shooting a PC monitorShutter item will return to white  When the shutter mode is Random  White spot detection How to useEtc Iris, etcMenu screen settings Menu screen flowE31 Exposure screen Setting procedureStep V.SCAN Random EEI OFF ShutterStep ScanProcess screen White Balance screenLens screen Menu Quick screen System Setting screenZoom Resetting menu settingsAbout ALC and EEI operations Specifications OthersE45 125.5 120Inch screw