Panasonic WV-BP554 manual AC Power Supply, Recommended wire gauge sizes for 24V AC line

Page 10

2.24 V AC Power Supply

Connect the power cable to the AC/DC compatible input terminal on the rear panel of the camera.

DC 12V

AC 24V

IN

IN

 

1

 

2

GND

24 VAC, 60 Hz

 

(19.5 V - 28 V)

 

 

Recommended wire gauge sizes for 24V AC line.

Copper wire

 

#24

#22

#20

#18

size (AWG)

 

(0.22mm2)

(0.33mm2)

(0.52mm2)

(0.83mm2)

 

 

 

 

 

 

 

Length

 

(m)

95

150

255

425

of Cable

 

 

 

 

 

 

 

 

 

 

 

 

(Approx.)

 

(ft)

314

495

842

1,403

 

 

 

 

 

 

 

Caution:

To prevent fire or electric shock hazard, a UL listed wire (VW-1, style 1007) should be used for the cable.

Video Cable

1.It is recommended to use a monitor whose resolu- tion is at least equal to that of the camera.

2.Set the termination switch to the 75Ω position on the last monitor.

A.Use a 75Ω coaxial cable.

B.Set the termination switch to the 75Ω position on the last monitor and to the Hi-Z position on the other monitors. Do not change the posi- tions after setting.

MonitorMonitor

 

VIDEO

75Ω

 

VIDEO

75Ω

IN

OUT

IN

OUT

 

 

Hi-Z

 

 

Hi-Z

C.The maximum extensible coaxial cable length between the camera and the monitor is shown below.

-8-

Image 10
Contents WV-BP550/WV-BP554 Symbol, within an equilateral triangle, is Contents Features PrefaceDo not attempt to disassemble the camera PrecautionsClean the CCD faceplate with care Handle the camera with careMajor Operating Controls and Their Functions WV-BP554Gen-lock Termination Switch Hi-Z, G/L 75Ω Auto Iris Lens ConnectorFlange-back Adjusting Ring Power indicatorAlarm Output Terminal Alarm OUT/GND Video Output Connector Video OUTPower Cord Socket AC/DC Compatible Input Terminal DC 12V IN/AC 24VWV-BP550 120V AC 60Hz DC Power SupplyConnections WV-BP554 12V DC/24V ACAC Power Supply Recommended wire gauge sizes for 24V AC lineRG-6U Installation of Auto Iris Lens Connector Mounting the Lens Focus or FLANGE-BACK Adjustment Mounting from the bottom Installation of CameraMounting from the top SET UP Camera Setup MenuMotion Detector Setup Operation All Reset OperationEditing the CAM SET UP Menu Opening the Setup MenuImportant Notice Editing the Special menu To edit the Camera ID Setting ProceduresCamera Identification Camera ID Setting To enter a blank space in the Camera IDTo erase all characters in the editing area Light Control Setting ALC/ELCTo return to the CAM SET UP menu To determine the display position of the Camera IDALC Mode with SUPER-D on Super Dynamic Function SUPER-DALC Mode with SUPER-D OFF and ELC Mode Shutter Speed Setting Shutter Gain Control Setting AGC ON/OFF Electronic Sensitivity Enhancement Sens UPSynchronization Setting Sync Important NoticesVS Gen-lock Mode Extvs EntLine-lock Sync Mode LL Motion Detector Setting Motion DET Lens Drive Signal Selection Lens DriveSpecial Menu Special Aperture Gain Setting AP GainPedestal Level Setting Pedestal Camera Picture Upside Down PositioningPrevention of Blooming and Smear Specifications Standard Accessories Optional AccessoriesVideo Imaging Systems Company Regional Offices