9. Special Menu (SPECIAL)

This menu lets you adjust and set up the video signal of the camera to meet your requirements.

Move the cursor to END on the bottom line of the CAM

SET UP menu and press or simultaneously for 2 seconds or longer. The SPECIAL menu appears on the monitor as shown below.

 

** CAM SET UP **

** SPECIAL **

 

CAMERA ID

OFF

UP SIDE DOWN

OFF

 

ALC/ELC

ALC

 

SHUTTER

---

 

AP GAIN

....I....

AGC

 

ON

 

PEDESTAL

.I

SENS

UP

OFF

 

 

-

+

SYNC

 

INT

 

 

 

 

MOTION DET

OFF

CAMERA RESET

PUSH SW

 

LENS

DRIVE

DC

 

 

 

 

SET UP ENABLE

RET END

 

 

 

END

 

 

9-1. Camera Picture Upside Down Positioning

(UP SIDE DOWN)

1.Move the cursor to the UP SIDE DOWN parameter.

2.Select ON when you want to turn the picture

upside down.

9-2. Aperture Gain Setting (AP GAIN)

1.Move the cursor to the AP GAIN parameter.

2.While observing the vector scope or video monitor, move the “I” cursor to adjust the aperture gain level.

9-3. Pedestal Level Setting (PEDESTAL)

1.Move the cursor to the PEDESTAL parameter.

2.While observing the wave form monitor/oscillo- scope or video monitor, move the “I” cursor to adjust the pedestal level (black level).

To reset to the factory settings

1.Move the cursor to the CAMERA RESET parame- ter. The words PUSH SW start blinking.

2.While holding down and , press for 2 seconds or longer. The camera is reset to the fac- tory settings.

To close the SPECIAL menu and return to the CAM SET UP menu

Move the cursor to RET and press .

To close the SPECIAL menu and return to the camera picture

Move the cursor to END and press .

-30-

Image 32
Contents WV-BP550/WV-BP554 Symbol, within an equilateral triangle, is Contents Features PrefacePrecautions Clean the CCD faceplate with careDo not attempt to disassemble the camera Handle the camera with careMajor Operating Controls and Their Functions WV-BP554Auto Iris Lens Connector Flange-back Adjusting RingGen-lock Termination Switch Hi-Z, G/L 75Ω Power indicatorVideo Output Connector Video OUT Power Cord SocketAlarm Output Terminal Alarm OUT/GND AC/DC Compatible Input Terminal DC 12V IN/AC 24VDC Power Supply ConnectionsWV-BP550 120V AC 60Hz WV-BP554 12V DC/24V ACAC Power Supply Recommended wire gauge sizes for 24V AC lineRG-6U Installation of Auto Iris Lens Connector Mounting the Lens Focus or FLANGE-BACK Adjustment Mounting from the top Installation of CameraMounting from the bottom SET UP Camera Setup MenuMotion Detector Setup Operation All Reset OperationImportant Notice Opening the Setup MenuEditing the CAM SET UP Menu Editing the Special menu Setting Procedures Camera Identification Camera ID SettingTo edit the Camera ID To enter a blank space in the Camera IDLight Control Setting ALC/ELC To return to the CAM SET UP menuTo erase all characters in the editing area To determine the display position of the Camera IDALC Mode with SUPER-D on Super Dynamic Function SUPER-DALC Mode with SUPER-D OFF and ELC Mode Shutter Speed Setting Shutter Gain Control Setting AGC ON/OFF Electronic Sensitivity Enhancement Sens UPSynchronization Setting Sync Important NoticesVS Gen-lock Mode Extvs EntLine-lock Sync Mode LL Motion Detector Setting Motion DET Lens Drive Signal Selection Lens DriveAperture Gain Setting AP Gain Pedestal Level Setting PedestalSpecial Menu Special Camera Picture Upside Down PositioningPrevention of Blooming and Smear Specifications Standard Accessories Optional AccessoriesVideo Imaging Systems Company Regional Offices