Panasonic WV-BP554 manual Motion Detector Setting Motion DET

Page 30

(FINE adjustment can be made up to 22.5 degrees

by pressing or .)

Notes:

When the “I” cursor reaches the “+” end, it jumps back to “”. At the same time, COARSE is incremented by one step to enable a contin-

uous adjustment. The reverse takes place when the “I” cursor reaches the “” end.

When or is kept pressed for a second or longer, the “I” cursor moves faster.

To reset COARSE and FINE to the values pre-

set at the factory, press or simultane- ously. COARSE and FINE adjustments are preset at the factory to zero-crossing of the AC line phase.

If the AC line contains noise (spike noise, etc.), the stability of the vertical phase of the camera video output signal may be disturbed.

7.Motion Detector Setting (MOTION DET)

The motion detector detects the moving objects in the scene by monitoring the brightness level changes. You can select the level of sensitivity for motion detection.

When this camera is connected to a compatible intelli- gent CCTV system, the camera transmits an alarm sig- nal by multiplexing it with the video signal.

1.Move the cursor to the MOTION DET parameter and select ON.

2.Press . The MOTION DETECT menu appears on the monitor screen.

** CAM SET UP **

** MOTION DETECT **

 

CAMERA ID

OFF

LEVEL

....I....

ALC/ELC

 

ALC

SHUTTER

 

---

 

DISPLAY MODE

-

+

AGC

 

ON

 

 

 

SENS UP

 

OFF

 

ALARM

ON

 

SYNC

 

INT

 

 

MOTION DET

ON

MASK SET

 

 

LENS DRIVE

DC

 

 

 

END

SET UP ENABLE

RET END

 

 

 

 

 

 

 

 

3.Move the cursor to MASK SET and press . The MASK SET menu has 48 masks. To set MASK SET, proceed as described in steps 2 to 4 of “ALC mode with SUPER-D OFF and ELC mode” on page 22.

4.Move the cursor to the ALARM parameter and select ON or OFF to set the alarm in the DISPLAY MODE.

Note: When the system controller WV-RM70, WV- CU550 or WV-CU550A is used with this model, select OFF for ALARM.

5.Move the cursor to DISPLAY MODE and press to see the current setting. The masks that detect the brightness changes start blinking.

-28-

Image 30
Contents WV-BP550/WV-BP554 Symbol, within an equilateral triangle, is Contents Features PrefaceDo not attempt to disassemble the camera PrecautionsClean the CCD faceplate with care Handle the camera with careMajor Operating Controls and Their Functions WV-BP554Gen-lock Termination Switch Hi-Z, G/L 75Ω Auto Iris Lens ConnectorFlange-back Adjusting Ring Power indicatorAlarm Output Terminal Alarm OUT/GND Video Output Connector Video OUTPower Cord Socket AC/DC Compatible Input Terminal DC 12V IN/AC 24VWV-BP550 120V AC 60Hz DC Power SupplyConnections WV-BP554 12V DC/24V ACAC Power Supply Recommended wire gauge sizes for 24V AC lineRG-6U Installation of Auto Iris Lens Connector Mounting the Lens Focus or FLANGE-BACK Adjustment Installation of Camera Mounting from the bottomMounting from the top SET UP Camera Setup MenuMotion Detector Setup Operation All Reset OperationOpening the Setup Menu Editing the CAM SET UP MenuImportant Notice Editing the Special menu To edit the Camera ID Setting ProceduresCamera Identification Camera ID Setting To enter a blank space in the Camera IDTo erase all characters in the editing area Light Control Setting ALC/ELCTo return to the CAM SET UP menu To determine the display position of the Camera IDALC Mode with SUPER-D on Super Dynamic Function SUPER-DALC Mode with SUPER-D OFF and ELC Mode Shutter Speed Setting Shutter Gain Control Setting AGC ON/OFF Electronic Sensitivity Enhancement Sens UPSynchronization Setting Sync Important NoticesVS Gen-lock Mode Extvs EntLine-lock Sync Mode LL Motion Detector Setting Motion DET Lens Drive Signal Selection Lens DriveSpecial Menu Special Aperture Gain Setting AP GainPedestal Level Setting Pedestal Camera Picture Upside Down PositioningPrevention of Blooming and Smear Specifications Standard Accessories Optional AccessoriesVideo Imaging Systems Company Regional Offices