Panasonic WV-BP554 Light Control Setting ALC/ELC, To erase all characters in the editing area

Page 22

2.Move the pointer to the character to be edited by

pressing or . Then move the cursor to the character area and select a new character.

3.Press to determine the CAMERA ID.

To erase all characters in the editing area

Move the cursor to RESET and press . All charac- ters in the editing area disappear.

To determine the display position of the CAMERA ID

1.Move the cursor to POSI, and press . The dis- play shown below appears and the CAMERA ID starts blinking.

Blinking

WV-BP550

2.Move the CAMERA ID to the desired position by pressing / / / .

3.Press to fix the position of the CAMERA ID. The mode returns to the previous CAMERA ID menu.

Notes:

The CAMERA ID stops at the edges of the monitor screen.

The CAMERA ID moves faster if any of /

/ / is kept pressed for a second or longer.

To return to the CAM SET UP menu

Move the cursor to RET and press . The CAM SET UP menu appears.

2. Light Control Setting (ALC/ELC)

You can select the light control mode according to the lens type.

ALC: If you use the auto iris lens, select this parameter.

ELC: If you use a fixed or manual iris lens, select this parameter.

** CAM SET UP **

CAMERA ID

OFF

ALC/ELC

ALC

SHUTTER

---

 

AGC

 

ON

 

SENS

UP

OFF

 

SYNC

 

INT

 

MOTION DET

OFF

LENS

DRIVE

DC

 

END

SET UP ENABLE

1.Move the cursor to the ALC/ELC parameter.

2.Select ALC or ELC.

-20-

Image 22
Contents WV-BP550/WV-BP554 Symbol, within an equilateral triangle, is Contents Features PrefaceDo not attempt to disassemble the camera PrecautionsClean the CCD faceplate with care Handle the camera with careMajor Operating Controls and Their Functions WV-BP554Gen-lock Termination Switch Hi-Z, G/L 75Ω Auto Iris Lens ConnectorFlange-back Adjusting Ring Power indicatorAlarm Output Terminal Alarm OUT/GND Video Output Connector Video OUTPower Cord Socket AC/DC Compatible Input Terminal DC 12V IN/AC 24VWV-BP550 120V AC 60Hz DC Power SupplyConnections WV-BP554 12V DC/24V ACAC Power Supply Recommended wire gauge sizes for 24V AC lineRG-6U Installation of Auto Iris Lens Connector Mounting the Lens Focus or FLANGE-BACK Adjustment Mounting from the bottom Installation of CameraMounting from the top SET UP Camera Setup MenuMotion Detector Setup Operation All Reset Operation Editing the CAM SET UP Menu Opening the Setup Menu Important Notice Editing the Special menu To edit the Camera ID Setting ProceduresCamera Identification Camera ID Setting To enter a blank space in the Camera IDTo erase all characters in the editing area Light Control Setting ALC/ELCTo return to the CAM SET UP menu To determine the display position of the Camera IDALC Mode with SUPER-D on Super Dynamic Function SUPER-DALC Mode with SUPER-D OFF and ELC Mode Shutter Speed Setting Shutter Gain Control Setting AGC ON/OFF Electronic Sensitivity Enhancement Sens UPSynchronization Setting Sync Important NoticesVS Gen-lock Mode Extvs EntLine-lock Sync Mode LL Motion Detector Setting Motion DET Lens Drive Signal Selection Lens DriveSpecial Menu Special Aperture Gain Setting AP GainPedestal Level Setting Pedestal Camera Picture Upside Down PositioningPrevention of Blooming and Smear Specifications Standard Accessories Optional AccessoriesVideo Imaging Systems Company Regional Offices