Samsung SPD-1000 Auxiliary Video Out Port, Setting Termination Resistance, +12V Output Port

Page 11

Part Names and Functions

Camera ID

SW1-#1

SW1-#2

SW1-#3

SW1-#4

SW1-#5

SW1-#6

SW1-#7

SW1-#8

 

250

ON

ON

ON

ON

ON

OFF

ON

OFF

 

251

ON

ON

ON

ON

ON

OFF

ON

ON

 

252

ON

ON

ON

ON

ON

ON

OFF

OFF

 

253

ON

ON

ON

ON

ON

ON

OFF

ON

 

254

ON

ON

ON

ON

ON

ON

ON

OFF

 

255

ON

ON

ON

ON

ON

ON

ON

ON

 

Connect the controller and alarm input and output signal (main body port block)

Pin Order

Pin Name

Purpose

1

D+

RS-485 Data+

2

D-

RS-485 Data-

3

G

GND

4

S1

Alarm Signal Input Port #1

5

S2

Alarm Signal Input Port #2

6

G

GND

7

+V

+12V Output Port

8

NO

Alarm Signal Output Port #1 (For Normal Open)

9

NC

Alarm Signal Output Por #1 (For Normal Close)

10

CM

Alarm Signal Output (For Common)

Auxiliary Video Out Port

When the product is installed in a place where video signal connection through the BNC port is unavailable, you can connect a video cable using the Auxiliary Video Out Port. In this case, connect using the BNC auxiliary cable that is supplied as an accessory.

Setting Termination Resistance

In order to prevent signal reduction, the termination resistance of the 2 end units, which are the distant paths for camera and controller to be connected on the RS485 interface, should be connected. As the termination resistance is built in the camera, whether to make the termination resistance valid or invalid is selected with the DIP switch. See the connection diagram below for determining to which device the termination resistance will be connected to. Set up the termination resistance in the dark products. The installation distance of the product for the termination resistance setting should be less than 1.2 Km. (Maximum cable length is 1.2 Km according to the RS-485 standards.)

20

21

Image 11
Contents English Page Features Contents Persons is not recommended PrecautionsMain Body Port Block Rear panel BodySetting Baud Rate Based on DVR Model Camera Initial SettingsOn the Path Setting RS-485 TerminationSetting Camera ID Switch SW2 #7 SW2 #8SW1-#1 SW1-#2 SW1-#3 SW1-#4 SW1-#5 SW1-#6 SW1-#7 SW1-#8 100 SW1-#1 SW1-#2 SW1-#3 SW1-#4 SW1-#5 SW1-#6 SW1-#7 SW1-#8 150 +12V Output Port Setting Termination ResistanceAuxiliary Video Out Port Pin Order Pin Name PurposeFollowing products are provided separately InstallationProducts Sold Separately Preparation for CableWall MountSTB-230PW Cable Connection Installation of SPD-1000Camera holder Connect the Power Adapter’s plug to the Power Wall Mount STB-280PWInstallation cover along the groove Installing the SPD-1000 on a CeilingTo complete installation, rotate Installing the SPD-1000 Wall Mount Exposure Installing the Dome Housing STH-1000PIFunctional Description OSD Menu OrganizationON/OFF Zoom Tracking PTZ Camera User Menu SettingsCamera Setting Main MenuCamera exposure can be controlled WB ModeWhite Balance ExposureNo noise reduction effect Back LightSsnr Samsung Super Noise Reduction Sens-UpOthers Camera Setting OhterDay & Night Select the Preset number Set up the Zoom and Focus Sequence SettingSequence Setting Menu Clear SettingTrace T SettingTime can be set up by the unit of 1-59 SEC and 1-59 MIN Pan 350˚ Auto Run in Pan directionTo enter the area name. a maximum of 12 letters English Chinese, numbers can be entered. When you finish inputtingName, adjust the position mark to SET using the joystick Area NameCamera Name Camera name is set up OSD SettingPreset Name Preset NameON/OFF Alarm is enabled in on mode Alarm SettingInput 1, Input 2 Alarm Input Mode/Priority/Method is set up Preset/Swing/Group/Tour/Trace/A.PANInitialization Menu Status of dome camera setting is displayedInitialize StatusProduct Structure Auto/Manual1/50~1/120000 SpecificationsInstallation 2 Mini PTZ Dome Camera Control Declaration of Conformity