Samsung SPD-1000 user manual White Balance, Exposure, Camera exposure can be controlled, WB Mode

Page 19

Functional Description

White Balance

The White Balance function corrects the abnormal white colour into the normal white colour under any colour temperature lighting.

Select the mode among ATW, AWC and Manual. ATW is selected by default.

Camera Setting

Focus

 

White Balance

ATW(O)

Exposure

 

Back Light

OFF

AGC

NORMAL

SSNR

LOW

Day & Night

COLOR

Others

 

WB Mode

ATW: Balances the colour automatically depending on the source of light from 1,800~10,500K colour temperature.

* Indoor[ATW(I)] : Use this mode in the area under the limited colour temperature.

* Outdoor[ATW(O)] : Use this mode in the area under the broad colour temperature.

AWC: Set up the lighting to the objects and corrects the right colour temperature to that of a white object. Camera works under the setup conditions. For the most appropriate condition under the current illumination, capture the white paper and then change the mode into AWC. Press the Enter key and then AWC Start will be displayed. When the adjustment is completed after pressing the Enter key for AWC Start, go to the upper menu. When conditions change, adjust the white balance function again.

Manual: Fine tuning is possible through this manual control mode. Select the colour temperature and increase or decrease the Red or Blue values to shift the colour of the object.

*Red : Red Gain can be changed.

*Blue : Blue Gain can be changed.

Notes

• White Balance may not function properly under the following conditions.

When the colour temperature surrounding the object is very high. (e.g. clear sky or sunset)

When it is dark around the object.

When the camera is pointing towards a fluorescent lamp directly or when lighting conditions change a lot.

Exposure

Camera exposure can be controlled.

Camera Setting

 

Exposure

 

Focus

 

Brightness

025

White Balance

ATW(O)

Iris

AUTO

Exposure

 

Shtter

---

Back Light

OFF

Sens-Up

AUTO

AGC

NORMAL

 

 

SSNR

LOW

 

 

Day & Night

COLOR

 

 

Others

 

 

 

Brightness: The brightness of the screen can be adjusted.

Iris: Auto mode or manual mode can be selected.

Auto: The brightness of the image signal can be adjusted automatically depending on the amount of light.

Manual: The brightness of the image can be adjusted.

Shutter

---: Electronic shutter mode is enabled. The shutter speed is controlled automatically according to the brightness of the screen.

A.FLK: Use this mode when the screen flickers because of inconsistent frequency with the surrounding lights.

Manual: 1. Shutter speed can be controlled manually.

2.Shutter speed can be adjusted from 1/60(1/50) second to 1/120,000 second.

3.Sens-Up function can be operated manually from x2 ~ x128.

Notes

If the Shutter mode is ESC in the inner synchronization mode and the camera faces to the bright fluorescent lamp directly, the image may be unstable. Be careful to select the installation location.

If the Manual or A.FLK mode is selected for the Shutter menu, the Sens-Up function is disabled.

36

37

Image 19
Contents English Page Features Contents Persons is not recommended PrecautionsMain Body Port Block Rear panel BodySetting Baud Rate Based on DVR Model Camera Initial SettingsOn the Path Setting RS-485 TerminationSetting Camera ID Switch SW2 #7 SW2 #8SW1-#1 SW1-#2 SW1-#3 SW1-#4 SW1-#5 SW1-#6 SW1-#7 SW1-#8 100 SW1-#1 SW1-#2 SW1-#3 SW1-#4 SW1-#5 SW1-#6 SW1-#7 SW1-#8 150 +12V Output Port Setting Termination ResistanceAuxiliary Video Out Port Pin Order Pin Name PurposeFollowing products are provided separately InstallationProducts Sold Separately Preparation for CableWall MountSTB-230PW Cable Connection Installation of SPD-1000Camera holder Connect the Power Adapter’s plug to the Power Wall Mount STB-280PWTo complete installation, rotate Installing the SPD-1000 on a CeilingInstallation cover along the groove Installing the SPD-1000 Wall Mount Exposure Installing the Dome Housing STH-1000PIFunctional Description OSD Menu OrganizationON/OFF Zoom Tracking PTZ Camera User Menu SettingsCamera Setting Main MenuCamera exposure can be controlled WB ModeWhite Balance ExposureNo noise reduction effect Back LightSsnr Samsung Super Noise Reduction Sens-UpDay & Night Camera Setting OhterOthers Sequence Setting Menu Sequence SettingSelect the Preset number Set up the Zoom and Focus Clear SettingTrace T SettingTime can be set up by the unit of 1-59 SEC and 1-59 MIN Pan 350˚ Auto Run in Pan directionTo enter the area name. a maximum of 12 letters English Chinese, numbers can be entered. When you finish inputtingName, adjust the position mark to SET using the joystick Area NameCamera Name Camera name is set up OSD SettingPreset Name Preset NameON/OFF Alarm is enabled in on mode Alarm SettingInput 1, Input 2 Alarm Input Mode/Priority/Method is set up Preset/Swing/Group/Tour/Trace/A.PANInitialization Menu Status of dome camera setting is displayedInitialize StatusProduct Structure Installation 2 Mini PTZ Dome Camera Control SpecificationsAuto/Manual1/50~1/120000 Declaration of Conformity