Axis Communications M1014 user manual Access from the Internet, Set the Root Password

Page 7

AXIS M1014 Network Camera

Accessing the Product

Access from the Internet

Once connected, the Axis product is accessible on your local network (LAN). To access the product from the Internet you must configure your network router to allow incoming data traffic to the product. To do this, enable the NAT-traversal feature, which will attempt to automatically configure the router to allow access to the product. This is enabled from Setup > System Options >

Network > TCP/IP Advanced.

For more information, please see NAT traversal (port mapping) for IPv4, on page 35. See also AXIS Internet Dynamic DNS Service at www.axiscam.net For Technical notes on this and other topics, visit the Axis Support web at www.axis.com/techsup

Set the Root Password

To gain access to the Axis product, you must set the password for the default administrator user root. This is done in the Configure Root Password dialog, which appears when the product is accessed for the first time.

To prevent network eavesdropping, the root password can be set via an encrypted HTTPS connection, which requires an HTTPS certificate. HTTPS (Hypertext Transfer Protocol over SSL) is a protocol used to encrypt traffic between web browsers and servers. The HTTPS certificate ensures encrypted exchange of information.

To set the password via a standard HTTP connection, enter it directly in the first dialog.

To set the password via an encrypted HTTPS connection, follow these steps:

1.Click Create self-signed certificate.

2.Provide the requested information and click OK. The certificate is created and the password can now be set securely. All traffic to and from the product is encrypted from this point on.

3.Enter a password and then re-enter to confirm the spelling. Click OK. The password has now been configured.

Note

The default administrator user name root is permanent and cannot be deleted.

If the password for root is lost, the product must be reset to the factory default settings. See Reset to Factory Default Settings, on page 40.

Set Power Line Frequency

Power line frequency is set the first time the Axis product is accessed and can only be changed from Plain Config (see page 40) or by resetting the product to factory default.

7

Image 7
Contents Axis M1014 Network Camera Intellectual Property Rights SafetyAbout this document LiabilityAxis M1014 Network Camera Table of ContentsHardware Overview ConnectorsHardware Overview Power connector Mini DC connector LED IndicatorsColor Indication Accessing the Product Accessing the ProductAccess from a Browser Network TCP/IP Advanced Access from the InternetSet the Root Password Set Power Line FrequencyManual Trigger Go to Setup EventsLive View Controls on the Live ViewPTZ Controls Axis Media Control viewer toolbarAxis Media Control AMC How to Stream H.264Media Streams Media StreamsAlternative Methods of Accessing the Video Stream Axis M1014 Network Camera Setting Up the Product Setting Up the ProductBasic Setup Pixel Counter VideoVideo Video StreamImage Stream Profiles264 Image Appearance Camera SettingsExposure Settings View AreaGo to Video Overlay Image OverlayOverlay Image Go to Video Video Stream and select the Image tabPrivacy Mask Live View Config Default Viewer for BrowsersLive View Config User Defined Links Viewer SettingsBrowser Viewer Description PTZ Pan Tilt Zoom Preset PositionsGo to PTZ Preset Positions PTZ Pan Tilt ZoomControl Queue AdvancedControls Motion Detection DetectorsDetectors Camera TamperingMotion Detection Parameters Set Up Motion Detection WindowsLow level 0% Default valuesRecommended values Events EventsRecipient Setting Up an Action RuleRecipients Go to Events Action Rules and click AddGo to Events Schedules and click Add SchedulesRecurrences Go to Events Recipients and click AddContinuous Recording RecordingsRecordings Recording ListAxis M1014 Network Camera Users System OptionsSystem Options SecurityCertificates IeeeGo to System Options Security Certificates Basic TCP/IP SettingsDate & Time NetworkAdvanced TCP/IP Settings NAT traversal port mapping for IPv4 NTP ConfigurationHost Name Configuration Link-Local IPv4 AddressFTP QoS Quality of ServiceRTP/H.264 UPnPTM can be disabled under System Options Network UPnPTMSmtp email UPnPTMNetwork Share StorageBonjour SD CardSystem Overview MaintenanceSupport Support OverviewFile Upload Reset to Factory Default SettingsLogs & Reports ScriptingAxis M1014 Network Camera Checking the Firmware TroubleshootingTroubleshooting Emergency Recovery ProcedureProblems setting the IP address Symptoms, Possible Causes and Remedial ActionsProduct cannot be accessed from a browser Problems with the H.264 format Product is accessible locally but not externallyStatus and Network indicator LEDs are flashing red rapidly Storage and disk management problems Video and image problems, generalVideo Camera Settings Problems uploading filesTechnical Specifications Technical SpecificationsDimensions Maintenance Installation aidsPower ConnectorsPerformance Considerations M1.8