Axis Communications M1014 Controls on the Live View, Manual Trigger, Go to Setup Events

Page 8

AXIS M1014 Network Camera

Accessing the Product

Select the power line frequency (50 Hz or 60 Hz) used at the location of the Axis product. Selecting the wrong frequency may cause image flicker if the product is used in fluorescent light environments.

When using 50 Hz, the maximum frame rate is limited to 25 fps.

Note

Power line frequency is different in different geographic regions. In the Americas, 60 Hz is usually used; most other parts of the world use 50 Hz. Local variations may apply, always check with the local authorities.

The Live View Page

The controls and layout of the Live View page may have been customized to meet specific installation requirements and user preferences. Consequently, some of the examples and functions featured here may differ from those displayed in your own Live View page. The following provides an overview of each available control.

Controls on the Live View Page

Click View size to scale the image down to 800 pixels wide or to full scale. Only available in MJPEG.

The Stream Profile drop-down list allows you to select a customized or pre-programmed stream profile. Stream profiles are configured under Video > Stream Profiles. See Stream Profiles, on page 15.

The Manual Trigger button is used to trigger an action rule from the Live View page; see page 8 . Enable this button from Live View Config > Action Buttons.

Click Snapshot to save a snapshot of the video image. Right-click the video image to save it in JPEG format on your computer. This button is primarily intended for use when the AXIS Media Control viewer toolbar is not available. Enable this button from Live View Config > Action Buttons.

Manual Trigger

The Manual Trigger is used to trigger an action rule from the Live View page. The manual trigger can for example be used to validate actions during product installation and configuration.

To configure the manual trigger:

1.Go to Setup > Events.

2.Click Add to add a new action rule.

3.From the Trigger drop-down list, select Input Signal.

4.From the second drop-down list, select Manual Trigger.

5.Select the desired action and configure the other settings as required. For more information about action rules, see Events, on page 26.

To show the manual trigger buttons in the Live View page:

1.Go to Setup > Live View Layout.

2.Under Action Buttons, select Show manual trigger button.

8

Image 8
Contents Axis M1014 Network Camera Safety About this documentLiability Intellectual Property RightsTable of Contents Axis M1014 Network CameraHardware Overview ConnectorsHardware Overview Color Indication LED IndicatorsPower connector Mini DC connector Access from a Browser Accessing the ProductAccessing the Product Access from the Internet Set the Root PasswordSet Power Line Frequency Network TCP/IP AdvancedGo to Setup Events Live ViewControls on the Live View Manual TriggerAxis Media Control viewer toolbar PTZ ControlsHow to Stream H.264 Media StreamsMedia Streams Axis Media Control AMCAlternative Methods of Accessing the Video Stream Axis M1014 Network Camera Basic Setup Setting Up the ProductSetting Up the Product Video VideoVideo Stream Pixel Counter264 Stream ProfilesImage Camera Settings Exposure SettingsView Area Image AppearanceOverlay Overlay ImageGo to Video Video Stream and select the Image tab Go to Video Overlay ImagePrivacy Mask Live View Config Default Viewer for BrowsersLive View Config Browser Viewer Description Viewer SettingsUser Defined Links Preset Positions Go to PTZ Preset PositionsPTZ Pan Tilt Zoom PTZ Pan Tilt ZoomControls AdvancedControl Queue Detectors DetectorsCamera Tampering Motion DetectionSet Up Motion Detection Windows Motion Detection ParametersRecommended values Default valuesLow level 0% Events EventsSetting Up an Action Rule RecipientsGo to Events Action Rules and click Add RecipientSchedules RecurrencesGo to Events Recipients and click Add Go to Events Schedules and click AddRecordings RecordingsRecording List Continuous RecordingAxis M1014 Network Camera System Options System OptionsSecurity UsersIeee CertificatesBasic TCP/IP Settings Date & TimeNetwork Go to System Options Security CertificatesAdvanced TCP/IP Settings NTP Configuration Host Name ConfigurationLink-Local IPv4 Address NAT traversal port mapping for IPv4QoS Quality of Service FTPUPnPTM can be disabled under System Options Network UPnPTM Smtp emailUPnPTM RTP/H.264Storage BonjourSD Card Network ShareMaintenance SupportSupport Overview System OverviewReset to Factory Default Settings Logs & ReportsScripting File UploadAxis M1014 Network Camera Troubleshooting TroubleshootingEmergency Recovery Procedure Checking the FirmwareProduct cannot be accessed from a browser Symptoms, Possible Causes and Remedial ActionsProblems setting the IP address Status and Network indicator LEDs are flashing red rapidly Product is accessible locally but not externallyProblems with the H.264 format Video and image problems, general Video Camera SettingsProblems uploading files Storage and disk management problemsTechnical Specifications Technical SpecificationsMaintenance Installation aids PowerConnectors DimensionsPerformance Considerations M1.8