'0'-'0' (30h, 30h): This operation is "Set parameter" type.

'0'-'0'-'0'-'3' (30h, 30h, 30h, 33h): Number of temperature sensors are 3 (0003h).

'0'-'0'-'0'-'1' (30h, 30h, 30h, 31h): temperature sensor is #1.

ETX (03h): End of Message

Check code

BCC: Block Check Code

Refer to the section 4.5 “Check code” for a BCC calculation.

Delimiter

CR (0Dh): End of packet

Step 3. The controller requests the monitor to send the temperature from the selected sensor.

 

Header

Message

Check code

Delimiter

SOH-'0'-Monitor ID-'0'-'C'-'0'-'6'

STX-'0'-'2'-'7'-'9'-ETX

BCC

CR

Header

 

 

 

SOH

(01h): Start of Header

 

 

 

'0'

(30h): Reserved

 

 

 

Monitor ID: Specify the Monitor ID which you want to get a value. Ex.) If Monitor ID is '1', specify 'A'.

'0' (30h): Message sender is the controller.

'C' (43h): Message Type is "Get parameter".

'0'-'6' (30h, 36h): Message length is 6 bytes.

Message

STX (02h): Start of Message

'0'-'2' (30h, 32h): Operation code page number is 2.

'7'-'9' (37h, 39h): Operation code is 79h (in the page 2).

ETX (03h): End of Message

Check code

BCC: Block Check Code

Refer to the section 4.5 “Check code” for a BCC calculation.

Delimiter

CR (0Dh): End of packet

Step 4. The monitor replies a temperature of selected sensor.

Header

Message

Check code

Delimiter

SOH-'0'-'0'-Monitor ID-'D'-'1'-'2'

STX-'0'-'0'-'0'-'2'-'7'-'9'-'0'-'0'

BCC

CR

-'F'-'F'-'F'-'F'-'0'-'0'-'3'-'2'-ETX

Header

SOH (01h): Start of Header

'0' (30h): Reserved

'0' (30h): Message receiver is the controller.

Monitor ID: Indicate a replying Monitor ID.

Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.

'D' (44h): Message Type is "Get parameter reply".

'1'-'2' (31h, 32h): Message length is 18 bytes.

Message

STX (02h): Start of Message

'0'-'0' (30h, 30h): Result code. No error.

'0'-'2' (30h, 32h): Operation code page number is 2.

'7'-'9' (37h, 39h): Operation code is 79h (in the page 2).

'0'-'0' (30h, 30h): This operation is "Set parameter" type.

'F'-'F'-'F'-'F' (46h, 46h, 46h, 46h): Maximum value.

'0'-'0'-'3'-'2' (30h, 30h, 33h, 32h): The temperature is 25 degrees Celsius.

(24/72)

Image 24
Contents External Control 10.1 Application II. Preparation Connectors and wiring RS-232C Remote controlLAN control Communication timing AsciiCommunication Format Get Parameter Reply MonitorHeader block format fixed length ALLPage Message block format STXETX MSB LSB10/72 Check code SOHDelimiter Message type Get current Parameter from a monitor00h No Error Get parameter replySet parameter ETX MSB LSBSet parameter reply Current conditionCommands Save Current Settings Send 0730h, 37h as Get Timing Report command Get Timing Report and Timing replyNull Message IV. Control Commands Typical procedure example How to change the Backlight settingBCC Message Check code Delimiter Header Message Check code Delimiter SOH-0-Monitor ID-0-E-0-A STX-0-2-7-8-0-0-0-1-ETX SOH-0-Monitor ID-0-C-0-6 STX-0-2-7-9-ETX Readout value is 2s complement Operation Code OP code Table Dicom SIMPosition 00h 20h Left side OP code Parameter Remarks Cod Pag Input Resolution DAh Surround HdmiRGB/HV PIPOSD 02h 7Dh None DVI-PC DVI-HDScart IP ON/PROGRESSIVEMute Unmute Screen Mute Screen Mute on Screen Mute OFF MTS‘SURROUND’ PIP ON/OFFOP code Parameter Remarks Cod Pag PIP Input 02h 73h No mean Power control procedure Power status readCR 0Dh End of packet 37/72 Power control Controller requests the monitor to control monitor powerDelimiter CR 0Dh End of packet 39/72 Asset Data read and write Asset Data Read Request and replyDelimiter CR 0Dh End of packet 41/72 Asset Data write CR 0Dh End of packet 43/72 Date & Time read and write Date & Time ReadBCC DS-ETX MN Minutes 0-030h, 30h Date & Time Write Check code Delimiter Delimiter CR 0Dh End of packet 48/72 Schedule read and write Schedule ReadB33h, 42h C33h, 43h On timer isnt set Page BCC OFF HOUR-OFF MIN-INPUT-WD-FL-ETX B33h, 42h 59 =3Bh C33h, 43h Off timer isn’t set PG-ON HOURS-ON MIN-OFF HOURS-OFF MIN-INPUT-WD-FL-P Mode Schedule WritePage BCC OFF HOUR-OFF MIN-INPUT-WD-FL-P Mode 57/72 SOH-0-Monitor ID-0-A-0-A STX-C-2-1-5-PG-EN-ETX Delimiter CR 0Dh End of packet 59/72 STX-C-2-1-4-PG-ON HOUR-ON MIN SOH-0-0-Monitor ID-B-1-8 STX-C-3-1-4-ST-PG-ON HOUR-ON MIN 030h, 30h 731h, 37h 23 =17h 831h, 38h Off timer isnt set SOH-0-0-Monitor ID-B-0-C STX-C-3-1-5-ST-PG-EN-ETX Self diagnosis Self-diagnosis status readPage Serial No. & Model Name Read Serial No. ReadModel Name Read Security Lock Security Lock ControlSTX-C-3-1-D-ST-EN-ETX Direct TV Chanel Read & Write Direct TV Chanel Read & ReplyDirect TV Chanel Write & Reply All data are subject to change without notice