III.Communication specification 3. Communication Parameter
3.1 RS-232C Remote control
(1) | Communication system | Asynchronous |
(2) | Interface | |
(3) | Baud rate | 9600bps |
(4) | Data length | 8bits |
(5) | Parity | None |
(6) | Stop bit | 1 bit |
(7) | Communication code | ASCII |
3.2 LAN control
(1) | Communication system | TCP/IP (Internet protocol suite) |
(2) | Interface | Ethernet (CSMA/CD) |
(3) | Communication layer | Transport layer (TCP) |
(4) | IP address | * Using the payload of TCP segment. |
(Default) 192.168.0.10 | ||
|
| * If you need to change, |
(5) | Port No. | Please refer “Network settings” on User’s manual. |
7142 (Fixed) |
(Note)
The monitor will disconnect the connection if no packet data is received for 15 minutes.
And the controller (PC) has to
3.3 Communication timing
The controller should wait for a packet interval before next command is sent. The packet interval needs to be longer than 600msec for the LCD monitor.
(5/72)