| Header | Message | Check code | Delimiter |
|
| BCC | CR | |
Header |
|
|
| |
SOH | (01h): Start Of Header |
|
|
|
'0' | (30h): Reserved |
|
|
|
Monitor ID: Specify the Monitor ID of which you want to change a setting. Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
Message
STX (02h): Start of Message
PG: Program No.
EN: Enable /Disable
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
4) The monitor replies a data for confirmation.
Header | Message | Check code | Delimiter |
BCC | CR |
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message type is "Command reply".
Message
STX (02h): Start of Message
ST: Enable/Disable Schedule Status command
EN: Enable /Disable
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
(58/72)