NEC RS-232C manual Header block format fixed length, All

Page 7

4.1 Header block format (fixed length)

Header

Message

Check code

Delimiter

SOH

Reserved

Destination

Source

Message

Message

'0'

Type

Length

1st

2nd

3rd

4th

5th

6th -7th

1stbyte) SOH: Start of Header

ASCII SOH (01h)

2ndbyte) Reserved: Reserved for future extensions. On this monitor, it must be ASCII '0'(30h).

3rdbyte) Destination: Destination equipment ID. (Receiver)

Specify a commands receiver’s address.

The controller sets the “MONITOR ID” or “GROUP ID” of the monitor controlled in here. On the reply, the monitor sets ‘0’ (30h), always.

“MONITOR ID”, “GROUP ID” to “Destination Address” conversion table is as follows,

Monitor

Destination

Monitor

Destination

Monitor

Destination

Monitor

Destination

ID

Address

ID

Address

ID

Address

ID

Address

1

41h(‘A’)

26

5Ah(‘Z’)

51

73h

76

8Ch

2

42h(‘B’)

27

5Bh

52

74h

77

8Dh

3

43h(‘C’)

28

5Ch

53

75h

78

8Eh

4

44h(‘D’)

29

5Dh

54

76h

79

8Fh

5

45h(‘E’)

30

5Eh

55

77h

80

90h

6

46h(‘F’)

31

5Fh

56

78h

81

91h

7

47h(‘G’)

32

60h

57

79h

82

92h

8

48h(‘H’)

33

61h

58

7Ah

83

93h

9

49h(‘I’)

34

62h

59

7Bh

84

94h

10

4Ah(‘J’)

35

63h

60

7Ch

85

95h

11

4Bh(‘K’)

36

64h

61

7Dh

86

96h

12

4Ch(‘L’)

37

65h

62

7Eh

87

97h

13

4Dh(‘M’)

38

66h

63

7Fh

88

98h

14

4Eh(‘N’)

39

67h

64

80h

89

99h

15

4Fh(‘O’)

40

68h

65

81h

90

9Ah

16

50h(‘P’)

41

69h

66

82h

91

9Bh

17

51h(‘Q’)

42

6Ah

67

83h

92

9Ch

18

52h(‘R’)

43

6Bh

68

84h

93

9Dh

19

53h(‘S’)

44

6Ch

69

85h

94

9Eh

20

54h(‘T’)

45

6Dh

70

86h

95

9Fh

21

55h(‘U’)

46

6Eh

71

87h

96

A0h

22

56h(‘V’)

47

6Fh

72

88h

97

A1h

23

57h(‘W’)

48

70h

73

89h

98

A2h

24

58h(‘X’)

49

71h

74

8Ah

99

A3h

25

59h(‘Y’)

50

72h

75

8Bh

100

A4h

ALL

2Ah(‘*’)

 

 

 

 

 

 

Group

Destination

ID

Address

A31h(‘1’)

B32h(‘2’)

C33h(‘3’)

Group

Destination

ID

Address

D34h(‘4’)

E35h(‘5’)

F36h(‘6’)

Group

Destination

ID

Address

G37h(‘7’)

H38h(‘8’)

I39h(‘9’)

Group

Destination

ID

Address

J

3Ah(‘:’)

 

 

Ex.) If you want to control a monitor that has the "ID No." as '1', specify a destination address

(7/72)

Image 7
Contents External Control 10.1 Application RS-232C Remote control II. Preparation Connectors and wiring LAN control Ascii Communication timingGet Parameter Reply Monitor Communication FormatALL Header block format fixed lengthPage MSB LSB Message block formatSTX ETX10/72 SOH Check codeDelimiter Get current Parameter from a monitor Message typeGet parameter reply 00h No ErrorETX MSB LSB Set parameterCurrent condition Set parameter replySave Current Settings CommandsGet Timing Report and Timing reply  Send 0730h, 37h as Get Timing Report commandNull Message How to change the Backlight setting IV. Control Commands Typical procedure exampleBCC Message Check code Delimiter Header Message Check code Delimiter SOH-0-Monitor ID-0-E-0-A STX-0-2-7-8-0-0-0-1-ETX SOH-0-Monitor ID-0-C-0-6 STX-0-2-7-9-ETX Readout value is 2s complement Dicom SIM Operation Code OP code TablePosition 00h 20h Left side OP code Parameter Remarks Cod Pag Input Resolution DAh Hdmi SurroundPIP RGB/HVOSD 02h 7Dh None IP ON/PROGRESSIVE DVI-PCDVI-HD ScartPIP ON/OFF Mute Unmute Screen MuteScreen Mute on Screen Mute OFF MTS ‘SURROUND’OP code Parameter Remarks Cod Pag PIP Input 02h 73h No mean Power status read Power control procedureCR 0Dh End of packet 37/72 Controller requests the monitor to control monitor power Power controlDelimiter CR 0Dh End of packet 39/72 Asset Data Read Request and reply Asset Data read and writeDelimiter CR 0Dh End of packet 41/72 Asset Data write CR 0Dh End of packet 43/72 Date & Time Read Date & Time read and writeBCC DS-ETX MN Minutes 0-030h, 30h Date & Time Write Check code Delimiter Delimiter CR 0Dh End of packet 48/72 Schedule Read Schedule read and writeB33h, 42h C33h, 43h On timer isnt set Page BCC OFF HOUR-OFF MIN-INPUT-WD-FL-ETX B33h, 42h 59 =3Bh C33h, 43h Off timer isn’t set Schedule Write PG-ON HOURS-ON MIN-OFF HOURS-OFF MIN-INPUT-WD-FL-P ModePage BCC OFF HOUR-OFF MIN-INPUT-WD-FL-P Mode 57/72 SOH-0-Monitor ID-0-A-0-A STX-C-2-1-5-PG-EN-ETX Delimiter CR 0Dh End of packet 59/72 STX-C-2-1-4-PG-ON HOUR-ON MIN SOH-0-0-Monitor ID-B-1-8 STX-C-3-1-4-ST-PG-ON HOUR-ON MIN 030h, 30h 731h, 37h 23 =17h 831h, 38h Off timer isnt set SOH-0-0-Monitor ID-B-0-C STX-C-3-1-5-ST-PG-EN-ETX Self-diagnosis status read Self diagnosisPage Serial No. Read Serial No. & Model Name ReadModel Name Read Security Lock Control Security LockSTX-C-3-1-D-ST-EN-ETX Direct TV Chanel Read & Reply Direct TV Chanel Read & WriteDirect TV Chanel Write & Reply All data are subject to change without notice
Related manuals