7. Power control procedure
7.1 Power status read
1) The controller requests the monitor to reply a current power status.
| Header | Message | Check code | Delimiter |
BCC | CR | |||
Header |
|
|
| |
SOH | (01h): Start Of Header |
|
|
|
'0' | (30h): Reserved |
|
|
|
Monitor ID: Specify the Monitor ID from which you want to get status. Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message Type is "Command".
Message
STX (02h): Start of Message
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor returns with the current power status.
Header | Message | Check code | Delimiter |
BCC | CR |
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message Type is "Command reply".
Message
STX(02h):Start of Message
00:No Error.
01:Unsupported.
0001: ON
0002:
0003: Suspend (power save)
0004: OFF (same as IR power off)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
(36/72)