TOA Electronics VM-2120 Function switch Settings An 8-bit DIP switch and selects, DC power input

Page 10

(2)Control input for broadcast activation [CTRL IN 1, 2, 3]

3 no-voltage make contact inputs, open voltage: 3.3 V DC, short-circuit current: under 1 mA

(3)24 V DC Power output [24 V OUT]

Supplies the 24 V DC/0.2 A power to an optional Amplifier Control Unit RU-2001/-2002.

29.Function switch [SETTINGS] An 8-bit DIP switch and selects

(1)Phantom power on-off for each input 1 – 3

(2)Telephone paging chime on-off

(3)7 different types of chime tones [2-tone chime/2- tone chime (fast repeat)/4-tone chime (Up)/Single- tone chime/4-tone chime (Up & Down)/Gong, and Pre-recorded chime*4], or chime-off

(4)MIC/LINE gain for inputs 1 – 3

Refer to page 48 "FUNCTION SWITCH OPERATION" for operation of the function switch.

30.Control input and output connector [CONTROL I/O]

A 25-pin, female D-sub connector.

(1)External control input

The following functions can be activated from external equipment.

• Message for an optional Voice Announcement Board

• Chime

• Power

• Emergency Broadcast

• Unit's broadcast cutoff

(2)Status output

When the unit is placed in the following status, the corresponding output is at make.

• Irregularity of communications with the Remote Microphone and an expansion amplifier.

• AC power ON

• DC power ON

• Irregularity of the sound source of the Voice Announcement Board.

• Failure (FAULT) indication on

• Power switch on

31.Attenuator control, external speaker input, speaker output connector

[ATTENUATOR CONTROL, EXTERNAL SP INPUT, DIRECT OUT, ZONE 1 – 5]

A dedicated, 16-pin plug-in screw connector and has the following input and outputs.

(1)External attenuator control output

[ATTENUATOR CONTROL]

An output terminal for bypassing the external attenuator.

(2)External speaker line Input

[EXTERNAL SP INPUT]

Accepts the signal from the external amplifier's speaker line. When the unit's broadcast cutoff input terminal of the Control Input and Output Connector (No. 30) is activated by an emergency equipment, the unit's power amplifier output is cut off, allowing the external signal to go through to the speakers in all zones.

(3)Direct speaker line output [DIRECT OUT] Outputs the signal directly from the power amplifier transformer output.*5 The volume level is the same as that which can be provided when the Zone Volume Control (No. 10) is set to the maximum position.

(4)Speaker output [SP OUT, ZONE 1 – 5] Connects to the speaker lines. This output is of 100 V line type, but can be converted to the 50 V or 70 V line type by internal connection change.

32.24 V DC power input

Connect the backup battery (maximum 24 V DC/7.5 A for VM-2120, 15 A for VM-2240) to this terminal.

33.AC inlet [AC mains]

Connect the supplied power cord to this inlet.

34.Fuse holder

The following miniature fuses (20 mm type) are used.

6.3 A (for 120 V AC version)

T2.5 A of time lag type (for VM-2120 230 V AC version), T3.15 A of time lag type (for VM-2240 230 V AC version)

Note: When the fuse is blown off, first remove the cause, then replace with the correct type specified on the unit.

35.Signal earth terminal

Note this terminal is not a safety earth. When there is hum noise, connecting this terminal to the body of connected equipment (BGM sound source, expansion amplifier, etc.) may reduce it.

*1 0 dB = 1 V

*2 Can be transformer-balanced with the addition of an optional IT-450 input transformer.

*3 Both the VM-2120 and the VM-2240 can also be combined.

*4 The chime sound source must be pre- recorded into a CF (CompactFlash) card to be inserted into the optional EV-200 Voice Announcement Board. (See p. 11.)

*5 Output signal source is switched to the EXTERNAL SP INPUT if the unit's broadcast cutoff is activated. See No. 31 (2).

10

Image 10
Contents System Management Amplifier Table of Contents Remote Microphone Installation When Installing the Unit Safety PrecautionsSafety Symbol and Message Conventions When the Unit is in UseWhen Installing the Unit System Management Amplifier VM-2120/VM-2240 FeaturesGeneral Description Remote Microphone RM-200MVM-2120/VM-2240 and RM-200M/RM-210 Handling PrecautionsInstallation Precautions VM-2120/VM-2240Nomenclature and Functions System Management Amplifier VM-2120/-2240 FrontRear DC power input Function switch Settings An 8-bit DIP switch and selectsControl input and output connector Control I/O Signal earth terminalVoice Announcement Board EV-200 Surveillance Board SV-200MRemote Microphone RM-200M Top Rear Right Side Left SideSystem Configuration Remote Microphone Operation Panel FunctionSpeaker zones with 2 VM amplifiers Connection between Remote Microphone and VM Amplifier Power Supply from the VM Amplifier to Remote MicrophoneConnection method vs. Distance Power supply using cables other than Category 5 STP cable Emergency Broadcast Equipment Keys/Indicators Used for Emergency BroadcastEmergency Alert and Evacuation Broadcast System management amplifier VM-2120/-2240Alert announcement example*3 Emergency Broadcast Operation Typical ExampleEvacuation announcement example*4 Page Emergency Broadcast Sequence Emergency modeRestoration to general-purpose broadcast Broadcast Operation AT the Amplifier Microphone Announcements When Operated by Control InputBackground Music Broadcast Remote Microphone GENERAL-PURPOSE Broadcast Broadcast volumeOperation and Display Sections Broadcast Operation Press-to-talk operation Operation below follows on the previousLock operation GENERAL-PURPOSE Broadcast Priority Broadcast Source-to-Priority RelationshipZone Broadcast source Made a broadcast last Priority Function during BGM Broadcast Available Chime Tone Types Chime FunctionHow the Chime Tone Is Used Independent chime activation remote control Operating procedureWestminster chime Choke Coil Installation Inputs 1 Input Transformer Installation and ITS Board ModificationTransformer Installation Remote Microphone RM or Telephone Paging TELSwitching Off the Phantom Power Supply RM/TEL input transformer boardEV-200 surveillance signal output Switch No Mounting AN Optional EV-200 Voice Announcement BoardCF Card security cover Speaker line surveillance activation time Mounting AN Optional SV-200M Surveillance BoardCommunications with VM VM-2120 or VM-2240 amplifier Surveillance I/O blank panel Two Amplifiers Stack-Connection Rack MountingAmplifier Input Connection Microphone Connection to the VM AmplifierTelephone Paging Input Connections External Attenuator Control Wiring Wire System ConnectionAttenuator C CONTROL*1 How to remove cables from connector Connector pin assignmentChanging the Speaker Line Voltage Control I/O Connector Functions Control I/O connector pin function tableElectrical characteristics Surveillance I/O Connector Functions Surveillance I/O connector pin function tableChime Selection table VM Amplifiers Internal Function Switches Connected unit No. table SW3 Remote Microphones Function SwitchesRM RM-200M Unit No. table Default setting Broadcast GROUP/ZONE SettingSetting example mark indicates Set state Routing AssignmentOperating Keys Recorded Message-to-Group assignmentZone-to-Group Assignment Operation Lighting statusAll zones setting and its cancellation Group setting contents check Indicator statusOperation for zone selection and its cancellation Dual indication of group and zone selectionsOperation for group selection and its cancellation Message setting contents checkDual indication of setting item and group selections Recorded Message-to-Group Assignment Operation Linkage Between Remote Microphone and ITS Extension Amplifiers Label Preparation Name Label PreparationRemote Microphones Label Preparation Pattern paper for hand writing Dimensional diagram for printing devices Recording Setting items and contentsCompactflash CF Card Recording Message Program/Sentence Composition ExampleMessage Program Example VM-2120/-2240 Specifications System Management Amplifier VM-2120/-2240To be AWG Remote Microphone RM-200M Remote microphone extension RM-210 AccessoriesOptional products Voice announcement board EV-200Page 133-12-726-70