TOA Electronics VM-2120 instruction manual Remote Microphone RM-200M

Page 69

Remote Microphone RM-200M

 

Power Source

 

24 V DC (Operating range: 14 – 28 V DC)

 

 

 

 

 

Power input jack:

Non-polarity type

 

 

 

 

 

Usable power input plug*3: Outer diameter ø5.5 mm, inner diameter

 

 

 

 

 

 

 

 

ø2.1 mm, length 9.5 mm

 

 

 

 

 

 

Current Consumption

 

100 mA maximum

 

 

 

 

 

 

 

Distortion

 

Under 1%

 

 

 

 

 

 

 

Frequency Response

 

100 – 20,000 Hz

 

 

 

 

 

 

 

Signal-to-Noise Ratio

 

Over 60 dB

 

 

 

 

 

 

 

Audio Output

 

0 dB*1, 600 , balanced

 

 

Microphone

 

Unidirectional electret condenser microphone

 

 

 

 

 

Speaker Control

 

Zones 1 – 5 or Zones 1 – 10 (2 stacked amplifiers connection*2),

 

 

 

 

 

Groups 1 – 2, and All-Zone Broadcast

 

 

 

 

Emergency Broadcast

Activation of Emergency Broadcast (pre-recorded announcement*2

 

 

 

 

 

or live microphone announcement) by Emergency Switch

 

 

 

 

 

Voice Message Control

Activation of 5 messages*2

 

 

No. of Connectable Units

Up to 4

 

 

 

 

 

 

Communication System

RS-485 Control

 

 

 

 

 

 

Volume Control

 

Microphone volume control

 

 

 

 

Connection Cable and Connector

Category 5 STP cable, RJ45 connector

 

 

 

 

 

Communication Distance

800 m maximum in total

 

 

 

 

 

DC Power Supply from Amplifier

Only a single unit can be power-supplied from VM-2120 or VM-

 

 

 

 

 

2240 amplifier. Line resistance: Under 40 (one way)

 

 

 

 

 

 

Finish

 

ABS resin

 

 

 

 

 

 

Dimensions

 

190 (w) x 76.5 (h) x 215 (d) mm (Gooseneck microphone excluded)

 

 

 

 

 

 

Weight

 

750 g

 

 

 

 

 

 

 

 

*1

0 dB = 1 V

 

 

 

 

 

*2

An optional EV-200 Board must be mounted in the VM-2120 or VM-2240 Amplifier.

 

The voice messages must be pre-recorded into a CF (CompactFlash) card to be inserted into the EV-200

 

Board.

 

 

 

 

 

*3

Suppliable AC adapters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Part name

 

Part code

 

Remarks

 

 

 

 

 

 

 

 

 

 

 

 

 

AD-4800 (US)

 

100-07-290-70

 

120 V AC version

 

 

 

 

 

 

 

 

 

 

 

 

 

AD-4800 (ER)

 

100-07-291-80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AD-4800 (BS)

 

100-07-292-10

 

230 V AC version

 

 

 

 

 

 

 

 

 

 

 

 

 

AD-4800 (AS)

 

100-07-293-60

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: The design and specifications are subject to change without notice for improvement.

Remote Microphone Extension RM-210

Current Consumption

20 mA maximum (in terms of RM-200M's DC power input)

 

 

Connection

Connection to RM-200M by dedicated cable

 

 

Function

Activation of Voice Announcement Board's voice messages when

 

controlling speakers in 10 zones at RM-200M

 

 

Finish

ABS resin

 

 

Dimensions

110 (w) x 76.5 (h) x 215 (d) mm

 

 

Weight

350 g

 

 

Note: The design and specifications are subject to change without notice for improvement.

69

Image 69
Contents System Management Amplifier Table of Contents Remote Microphone Installation Safety Symbol and Message Conventions Safety PrecautionsWhen Installing the Unit When the Unit is in UseWhen Installing the Unit General Description FeaturesSystem Management Amplifier VM-2120/VM-2240 Remote Microphone RM-200MInstallation Precautions Handling PrecautionsVM-2120/VM-2240 and RM-200M/RM-210 VM-2120/VM-2240System Management Amplifier VM-2120/-2240 Front Nomenclature and FunctionsRear Control input and output connector Control I/O Function switch Settings An 8-bit DIP switch and selectsDC power input Signal earth terminalSurveillance Board SV-200M Voice Announcement Board EV-200Remote Microphone RM-200M Top Left Side Rear Right SideRemote Microphone Operation Panel Function System ConfigurationSpeaker zones with 2 VM amplifiers Power Supply from the VM Amplifier to Remote Microphone Connection between Remote Microphone and VM AmplifierConnection method vs. Distance Power supply using cables other than Category 5 STP cable Emergency Alert and Evacuation Broadcast Keys/Indicators Used for Emergency BroadcastEmergency Broadcast Equipment System management amplifier VM-2120/-2240Emergency Broadcast Operation Typical Example Alert announcement example*3Evacuation announcement example*4 Page Emergency mode Emergency Broadcast SequenceRestoration to general-purpose broadcast Microphone Announcements When Operated by Control Input Broadcast Operation AT the AmplifierBackground Music Broadcast Broadcast volume Remote Microphone GENERAL-PURPOSE BroadcastOperation and Display Sections Broadcast Operation Operation below follows on the previous Press-to-talk operationLock operation Broadcast Source-to-Priority Relationship GENERAL-PURPOSE Broadcast PriorityZone Broadcast source Made a broadcast last Priority Function during BGM Broadcast Chime Function Available Chime Tone TypesHow the Chime Tone Is Used Operating procedure Independent chime activation remote controlWestminster chime Choke Coil Installation Transformer Installation Input Transformer Installation and ITS Board ModificationInputs 1 Remote Microphone RM or Telephone Paging TELRM/TEL input transformer board Switching Off the Phantom Power SupplyMounting AN Optional EV-200 Voice Announcement Board EV-200 surveillance signal output Switch NoCF Card security cover Mounting AN Optional SV-200M Surveillance Board Speaker line surveillance activation timeCommunications with VM VM-2120 or VM-2240 amplifier Surveillance I/O blank panel Amplifier Input Connection Rack MountingTwo Amplifiers Stack-Connection Microphone Connection to the VM AmplifierTelephone Paging Input Connections Wire System Connection External Attenuator Control WiringAttenuator C CONTROL*1 Connector pin assignment How to remove cables from connectorChanging the Speaker Line Voltage Control I/O connector pin function table Control I/O Connector FunctionsElectrical characteristics Surveillance I/O connector pin function table Surveillance I/O Connector FunctionsChime Selection table VM Amplifiers Internal Function Switches Remote Microphones Function Switches Connected unit No. table SW3RM RM-200M Unit No. table Setting example mark indicates Set state Broadcast GROUP/ZONE SettingDefault setting Routing AssignmentRecorded Message-to-Group assignment Operating KeysLighting status Zone-to-Group Assignment OperationAll zones setting and its cancellation Indicator status Group setting contents checkDual indication of group and zone selections Operation for zone selection and its cancellationMessage setting contents check Operation for group selection and its cancellationDual indication of setting item and group selections Recorded Message-to-Group Assignment Operation Linkage Between Remote Microphone and ITS Extension Name Label Preparation Amplifiers Label PreparationRemote Microphones Label Preparation Pattern paper for hand writing Dimensional diagram for printing devices Compactflash CF Card Recording Setting items and contentsRecording Message Program/Sentence Composition ExampleMessage Program Example VM-2120/-2240 System Management Amplifier VM-2120/-2240 SpecificationsTo be AWG Remote Microphone RM-200M Optional products AccessoriesRemote microphone extension RM-210 Voice announcement board EV-200Page 133-12-726-70