TOA Electronics VM-2120 Independent chime activation remote control, Operating procedure

Page 31

12.2.3. Independent chime activation (remote control)

A chime tone can be sounded when the broadcast of the sound source (Priority 3) connected to Inputs 1 – 3 not activated by remote control (CTRL IN 1,2,3) is started (and completed).

Have a chime tone remotely transmitted from the unit's rear panel-mounted CONTROL I/O connector pin No. 9 "Chime activation." (See p. 45 "CONTROL I/O CONNECTOR FUNCTIONS.") Make a chime activation switch and connect it to between the pin and GND terminal.

Broadcast sound source

Chime activation switch

Pin No. 9

CONTROL I/O D-sub connector

VM amplifier

One of Input 1 – 3

Chime activation

GND

[Operating procedure]

Step 1. Using the unit's front panel-mounted zone selector key (Zone 1 – 5) or All-zone broadcast key, select the desired zone(s) to broadcast the sound source connected to Input 1, 2, or 3.

 

 

 

 

 

 

 

Zone selector key [Zone 1 – 5]

 

 

 

 

 

 

 

 

All-zone broadcast key

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Master volume control

Zone volume control [Zone 1 – 5]

Note: The chime sound volume depends on the broadcast volume level adjusted with the master volume control and zone volume control.

Step 2. Turn on (make) the Chime switch. A pre-announcement chime tone will be sent out to the zone(s) selected in Step 1.

Chime activation switch

Pin No. 9

Make

Break

VM amplifier

Chime activation

GND

Pre-announcement chime tone

31

Image 31
Contents System Management Amplifier Table of Contents Remote Microphone Installation When the Unit is in Use Safety PrecautionsSafety Symbol and Message Conventions When Installing the UnitWhen Installing the Unit Remote Microphone RM-200M FeaturesGeneral Description System Management Amplifier VM-2120/VM-2240VM-2120/VM-2240 Handling PrecautionsInstallation Precautions VM-2120/VM-2240 and RM-200M/RM-210System Management Amplifier VM-2120/-2240 Front Nomenclature and FunctionsRear Signal earth terminal Function switch Settings An 8-bit DIP switch and selectsControl input and output connector Control I/O DC power inputSurveillance Board SV-200M Voice Announcement Board EV-200Remote Microphone RM-200M Top Left Side Rear Right SideRemote Microphone Operation Panel Function System ConfigurationSpeaker zones with 2 VM amplifiers Connection between Remote Microphone and VM Amplifier Power Supply from the VM Amplifier to Remote MicrophoneConnection method vs. Distance Power supply using cables other than Category 5 STP cable System management amplifier VM-2120/-2240 Keys/Indicators Used for Emergency BroadcastEmergency Alert and Evacuation Broadcast Emergency Broadcast EquipmentAlert announcement example*3 Emergency Broadcast Operation Typical ExampleEvacuation announcement example*4 Page Emergency Broadcast Sequence Emergency modeRestoration to general-purpose broadcast Broadcast Operation AT the Amplifier Microphone Announcements When Operated by Control InputBackground Music Broadcast Remote Microphone GENERAL-PURPOSE Broadcast Broadcast volumeOperation and Display Sections Broadcast Operation Operation below follows on the previous Press-to-talk operationLock operation Broadcast Source-to-Priority Relationship GENERAL-PURPOSE Broadcast Priority Zone Broadcast source Made a broadcast last Priority Function during BGM Broadcast Available Chime Tone Types Chime FunctionHow the Chime Tone Is Used Operating procedure Independent chime activation remote controlWestminster chime Choke Coil Installation Remote Microphone RM or Telephone Paging TEL Input Transformer Installation and ITS Board ModificationTransformer Installation Inputs 1RM/TEL input transformer board Switching Off the Phantom Power SupplyMounting AN Optional EV-200 Voice Announcement Board EV-200 surveillance signal output Switch NoCF Card security cover Speaker line surveillance activation time Mounting AN Optional SV-200M Surveillance BoardCommunications with VM VM-2120 or VM-2240 amplifier Surveillance I/O blank panel Microphone Connection to the VM Amplifier Rack MountingAmplifier Input Connection Two Amplifiers Stack-ConnectionTelephone Paging Input Connections Wire System Connection External Attenuator Control WiringAttenuator C CONTROL*1 How to remove cables from connector Connector pin assignmentChanging the Speaker Line Voltage Control I/O connector pin function table Control I/O Connector FunctionsElectrical characteristics Surveillance I/O connector pin function table Surveillance I/O Connector FunctionsChime Selection table VM Amplifiers Internal Function Switches Connected unit No. table SW3 Remote Microphones Function SwitchesRM RM-200M Unit No. table Routing Assignment Broadcast GROUP/ZONE SettingSetting example mark indicates Set state Default settingRecorded Message-to-Group assignment Operating KeysLighting status Zone-to-Group Assignment OperationAll zones setting and its cancellation Indicator status Group setting contents checkDual indication of group and zone selections Operation for zone selection and its cancellationOperation for group selection and its cancellation Message setting contents checkDual indication of setting item and group selections Recorded Message-to-Group Assignment Operation Linkage Between Remote Microphone and ITS Extension Amplifiers Label Preparation Name Label PreparationRemote Microphones Label Preparation Pattern paper for hand writing Dimensional diagram for printing devices Message Program/Sentence Composition Example Setting items and contentsCompactflash CF Card Recording RecordingMessage Program Example VM-2120/-2240 System Management Amplifier VM-2120/-2240 SpecificationsTo be AWG Remote Microphone RM-200M Voice announcement board EV-200 AccessoriesOptional products Remote microphone extension RM-210Page 133-12-726-70