24.5. Recorded Message-to-Group Assignment Operation

Here, the operation example of assigning Recorded Message 1 to Broadcast Groups 1, 3, and 4 will be explained. (See p. 52 "Message 1 to group" setting example.)

Step 1. Entry to recorded message setting mode

ZONE 1

ZONE 3

Reset

Press and release the Reset key while holding down the ZONE 1 and ZONE 3 keys. When all indicators for Zones 1 – 5 begins to flash (2 – 3 seconds after), release both the ZONE 1 and ZONE 3 keys.

Message 1

Message 5

The unit will be placed in recorded message setting mode.

The 5 indicators for ZONE 1 through ZONE 5 begin to flash. (They indicate Message 1 through Message 5.)

ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5

ALL

Operations of Steps 2 – 6 described hereafter are the same as those described in the previous section Control input/Telephone paging/Westminster chime-to-Group assignment. However, read 5 setting items of Inputs 1 – 3, TEL paging, and Westminster chime as Messages 1 – 5.

Group 1

Group 5

(Message 1)

 

Shown on the right is the status of each indicator that results

 

from the group number setting (Example. Groups 1, 3, and 4)

 

performed in Step 4.

 

ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5

ALL

58

Image 58
Contents System Management Amplifier Table of Contents Remote Microphone Installation When Installing the Unit Safety PrecautionsSafety Symbol and Message Conventions When the Unit is in UseWhen Installing the Unit System Management Amplifier VM-2120/VM-2240 FeaturesGeneral Description Remote Microphone RM-200MVM-2120/VM-2240 and RM-200M/RM-210 Handling PrecautionsInstallation Precautions VM-2120/VM-2240Nomenclature and Functions System Management Amplifier VM-2120/-2240 FrontRear DC power input Function switch Settings An 8-bit DIP switch and selectsControl input and output connector Control I/O Signal earth terminalVoice Announcement Board EV-200 Surveillance Board SV-200MRemote Microphone RM-200M Top Rear Right Side Left SideSystem Configuration Remote Microphone Operation Panel FunctionSpeaker zones with 2 VM amplifiers Connection between Remote Microphone and VM Amplifier Power Supply from the VM Amplifier to Remote MicrophoneConnection method vs. Distance Power supply using cables other than Category 5 STP cable Emergency Broadcast Equipment Keys/Indicators Used for Emergency BroadcastEmergency Alert and Evacuation Broadcast System management amplifier VM-2120/-2240Alert announcement example*3 Emergency Broadcast Operation Typical ExampleEvacuation announcement example*4 Page Emergency Broadcast Sequence Emergency modeRestoration to general-purpose broadcast Broadcast Operation AT the Amplifier Microphone Announcements When Operated by Control InputBackground Music Broadcast Remote Microphone GENERAL-PURPOSE Broadcast Broadcast volumeOperation and Display Sections Broadcast Operation Press-to-talk operation Operation below follows on the previousLock operation GENERAL-PURPOSE Broadcast Priority Broadcast Source-to-Priority RelationshipZone Broadcast source Made a broadcast last Priority Function during BGM Broadcast Available Chime Tone Types Chime FunctionHow the Chime Tone Is Used Independent chime activation remote control Operating procedureWestminster chime Choke Coil Installation Inputs 1 Input Transformer Installation and ITS Board ModificationTransformer Installation Remote Microphone RM or Telephone Paging TELSwitching Off the Phantom Power Supply RM/TEL input transformer boardEV-200 surveillance signal output Switch No Mounting AN Optional EV-200 Voice Announcement BoardCF Card security cover Speaker line surveillance activation time Mounting AN Optional SV-200M Surveillance BoardCommunications with VM VM-2120 or VM-2240 amplifier Surveillance I/O blank panel Two Amplifiers Stack-Connection Rack MountingAmplifier Input Connection Microphone Connection to the VM AmplifierTelephone Paging Input Connections External Attenuator Control Wiring Wire System ConnectionAttenuator C CONTROL*1 How to remove cables from connector Connector pin assignmentChanging the Speaker Line Voltage Control I/O Connector Functions Control I/O connector pin function tableElectrical characteristics Surveillance I/O Connector Functions Surveillance I/O connector pin function tableChime Selection table VM Amplifiers Internal Function Switches Connected unit No. table SW3 Remote Microphones Function SwitchesRM RM-200M Unit No. table Default setting Broadcast GROUP/ZONE SettingSetting example mark indicates Set state Routing AssignmentOperating Keys Recorded Message-to-Group assignmentZone-to-Group Assignment Operation Lighting statusAll zones setting and its cancellation Group setting contents check Indicator statusOperation for zone selection and its cancellation Dual indication of group and zone selectionsOperation for group selection and its cancellation Message setting contents checkDual indication of setting item and group selections Recorded Message-to-Group Assignment Operation Linkage Between Remote Microphone and ITS Extension Amplifiers Label Preparation Name Label PreparationRemote Microphones Label Preparation Pattern paper for hand writing Dimensional diagram for printing devices Recording Setting items and contentsCompactflash CF Card Recording Message Program/Sentence Composition ExampleMessage Program Example VM-2120/-2240 Specifications System Management Amplifier VM-2120/-2240To be AWG Remote Microphone RM-200M Remote microphone extension RM-210 AccessoriesOptional products Voice announcement board EV-200Page 133-12-726-70