TOA Electronics VM-2120 Control I/O Connector Functions, Control I/O connector pin function table

Page 45

21. CONTROL I/O CONNECTOR FUNCTIONS

The rear panel-mounted Control I/O connector enables the VM amplifier to be controlled or monitored by connected external equipment. Referring to the pin arrangement and functions, prepare the matching D-sub male connector (screw-lock type) for connection to the external equipment. (See p. 9, 10 No. 30 CONTROL I/O connector.)

VM amplifier's D-sub female connector

13 CONTROL I/O 1

Locking nut: 4-40 UNC

 

25

14

 

 

CONTROL I/O connector pin function table

 

 

 

 

 

 

 

Pin

Signal name

IN

 

Signal/logic

Function/status

No.

/OUT

 

 

 

 

 

 

 

 

 

 

 

1

AC power ON

OUT

 

Active Low

When AC power is on

 

 

 

 

 

 

2

DC power ON

OUT

 

Active Low

When DC power is on

 

 

 

 

 

 

3

Message 1 activation

IN

 

One-shot make

Activates EV-200 Board's Message 1.*1

4

Message 2 activation

IN

 

One-shot make

Activates EV-200 Board's Message 2.*1

5

Message 3 activation

IN

 

One-shot make

Activates EV-200 Board's Message 3.*1

6

Message 4 activation

IN

 

One-shot make

Activates EV-200 Board's Message 4.*1

7

Message 5 activation

IN

 

One-shot make

Activates EV-200 Board's Message 5.*1

8

VM amplifier's

IN

 

At make

Cuts off the VM amplifier's power amplifier

 

broadcast cutoff control

 

 

 

output.*1 *2 (External signals applied to

 

 

 

 

 

EXTERNAL SP INPUT go through to the

 

 

 

 

 

speakers.)

 

 

 

 

 

 

 

 

 

 

At break

The VM amplifier's power amplifier output is

 

 

 

 

 

resumed.

 

 

 

 

 

 

9

Chime activation

IN

 

Break-to-Make edge

Activates a start chime tone.

 

 

 

 

 

 

 

(6 built-in chimes)

 

 

Make-to-Break edge

Activates an end chime tone (4-tone Down).

 

 

 

 

 

 

10

Power ON/OFF control

IN

 

Break-to-Make edge

Turns power on.

 

 

 

 

 

 

 

 

 

 

Make-to-Break edge

Turns power off.

 

 

 

 

 

 

11

Westminster chime

IN

 

One-shot make

Activates the internal Westminster chime unit.

 

activation

 

 

 

 

 

 

 

 

 

 

12

Emergency alert

IN

 

One-shot make

Places the unit in "Emergency broadcast" mode,

 

activation

 

 

 

during which time an "Alert" announcement and

 

 

 

 

 

an "Evacuation" announcement are broadcast. *1

13

Emergency stop

IN

 

One-shot make

Resets the unit from "Emergency broadcast"

 

activation

 

 

 

mode.

 

 

 

 

 

 

14

Emergency evacuation

IN

 

One-shot make

Places the unit in "Emergency broadcast" mode,

 

activation

 

 

 

during which time an "Evacuation" announcement

 

 

 

 

 

is repeated. *1

15

Failure indicator control

IN

 

At make

The FAULT indicator lights to indicate external

 

 

 

 

 

equipment failure.

 

 

 

 

 

 

16

GND

 

 

 

 

 

 

 

 

 

 

17

GND

 

 

 

 

 

 

 

 

 

 

18

GND

 

 

 

 

 

 

 

 

 

 

19

GND

 

 

 

 

 

 

 

 

 

 

20

GND

 

 

 

 

 

 

 

 

 

 

21

Power switch on

OUT

 

Active Low

When the power switch is on by means of

 

 

 

 

 

manual or external control

 

 

 

 

 

 

45

Image 45
Contents System Management Amplifier Table of Contents Remote Microphone Installation Safety Symbol and Message Conventions Safety PrecautionsWhen Installing the Unit When the Unit is in UseWhen Installing the Unit General Description FeaturesSystem Management Amplifier VM-2120/VM-2240 Remote Microphone RM-200MInstallation Precautions Handling PrecautionsVM-2120/VM-2240 and RM-200M/RM-210 VM-2120/VM-2240System Management Amplifier VM-2120/-2240 Front Nomenclature and FunctionsRear Control input and output connector Control I/O Function switch Settings An 8-bit DIP switch and selectsDC power input Signal earth terminalSurveillance Board SV-200M Voice Announcement Board EV-200Remote Microphone RM-200M Top Left Side Rear Right SideRemote Microphone Operation Panel Function System ConfigurationSpeaker zones with 2 VM amplifiers Power Supply from the VM Amplifier to Remote Microphone Connection between Remote Microphone and VM AmplifierConnection method vs. Distance Power supply using cables other than Category 5 STP cable Emergency Alert and Evacuation Broadcast Keys/Indicators Used for Emergency BroadcastEmergency Broadcast Equipment System management amplifier VM-2120/-2240Emergency Broadcast Operation Typical Example Alert announcement example*3Evacuation announcement example*4 Page Emergency mode Emergency Broadcast SequenceRestoration to general-purpose broadcast Microphone Announcements When Operated by Control Input Broadcast Operation AT the AmplifierBackground Music Broadcast Broadcast volume Remote Microphone GENERAL-PURPOSE BroadcastOperation and Display Sections Broadcast Operation Operation below follows on the previous Press-to-talk operationLock operation Broadcast Source-to-Priority Relationship GENERAL-PURPOSE Broadcast PriorityZone Broadcast source Made a broadcast last Priority Function during BGM Broadcast Chime Function Available Chime Tone TypesHow the Chime Tone Is Used Operating procedure Independent chime activation remote controlWestminster chime Choke Coil Installation Transformer Installation Input Transformer Installation and ITS Board ModificationInputs 1 Remote Microphone RM or Telephone Paging TELRM/TEL input transformer board Switching Off the Phantom Power SupplyMounting AN Optional EV-200 Voice Announcement Board EV-200 surveillance signal output Switch NoCF Card security cover Mounting AN Optional SV-200M Surveillance Board Speaker line surveillance activation timeCommunications with VM VM-2120 or VM-2240 amplifier Surveillance I/O blank panel Amplifier Input Connection Rack MountingTwo Amplifiers Stack-Connection Microphone Connection to the VM AmplifierTelephone Paging Input Connections Wire System Connection External Attenuator Control WiringAttenuator C CONTROL*1 Connector pin assignment How to remove cables from connectorChanging the Speaker Line Voltage Control I/O connector pin function table Control I/O Connector FunctionsElectrical characteristics Surveillance I/O connector pin function table Surveillance I/O Connector FunctionsChime Selection table VM Amplifiers Internal Function Switches Remote Microphones Function Switches Connected unit No. table SW3RM RM-200M Unit No. table Setting example mark indicates Set state Broadcast GROUP/ZONE SettingDefault setting Routing AssignmentRecorded Message-to-Group assignment Operating KeysLighting status Zone-to-Group Assignment OperationAll zones setting and its cancellation Indicator status Group setting contents checkDual indication of group and zone selections Operation for zone selection and its cancellationMessage setting contents check Operation for group selection and its cancellationDual indication of setting item and group selections Recorded Message-to-Group Assignment Operation Linkage Between Remote Microphone and ITS Extension Name Label Preparation Amplifiers Label PreparationRemote Microphones Label Preparation Pattern paper for hand writing Dimensional diagram for printing devices Compactflash CF Card Recording Setting items and contentsRecording Message Program/Sentence Composition ExampleMessage Program Example VM-2120/-2240 System Management Amplifier VM-2120/-2240 SpecificationsTo be AWG Remote Microphone RM-200M Optional products AccessoriesRemote microphone extension RM-210 Voice announcement board EV-200Page 133-12-726-70