7. SYSTEM CONFIGURATION
7.1.Remote Microphone/VM Amplifier Configuration (The Number of Connected Units)
Set the total number (0 – 5) of equipment (up to 1
Remote |
| Remote |
| Remote |
| Remote |
microphone |
| microphone |
| microphone |
| microphone |
No. 1 |
| No. 2 |
| No. 3 |
| No. 4 |
|
|
|
|
|
|
|
The number of Remote Microphones (0 – 4 units)
Master VM
amplifier
Voice announcement board (optional)
(0 or 1 unit)
Set the Remote Microphone's Unit number (1 – 4) using DIP switches No. 1 and No. 2 on the microphone's right side panel. The Unit number may be set regardless of the unit's connection order. (See p. 49 "VM Amplifier's Internal Function Switches.")
7.2. Remote Microphone Operation Panel Function
The Zone/Message selector key function differs depending on the connected VM amplifier as described below.
(1) 5 speaker zones with 1 VM amplifier
Remote microphone
VM amplifier
Zone 1 – 5 selector key /indicator
14