Elmo manual For ISP-X/65, For ISP-X/135, IxR compensation

Page 39

39

7.3Velocity control using armature voltage feedback

The reference signal should be connected to the differential input and R3,R4 should be calculated and inserted according to:

R3 = R4 = 1.33xVdm

(Kohm)

Vdm - maximum reference

voltage at the differential input.

The armature voltage feedback will enter the error amplifier by inserting R8, calculated for the two voltage types as follows:

For ISP-X/65:

R8(65V) = 1.3xVam

(Kohm)

Vam - armature voltage at maximum application speed

For ISP-X/135:

R8(135V) = 0.73xVam(Kohm)

Vam - armature voltage at maximum application speed

IxR compensation

In order to improve the speed stability in various load conditions, an IxR compensation is required. This is achieved by:

-Connect the Current Feedback Monitor (terminal H-7,R-26a,E-J1/6) to input 1 (terminal H-1,R-32a,E-J1/3).

-Rotate T7 to max. CCW position (minimum IxR compensation).

-Insert R1 as follows:

3 x

Vam

R1 = ----------

(Kohm)

Rm

x Ip

Vam - Armature voltage at maximum application speed.

Ip - Amplifiers' rated peak current limit.

Rm - Total ohmic resistance of motor.

ISP - Rev 6/95

Image 39
Contents Rev 6/95 ISP Rev 6/95 ELMO-WARRANTY Performance Read chapters Table of Contents Balance adjustment Current limit adjustment Standard features DescriptionProtective functions Type Designation Technical specificationsOperation of the servo control Inputs Velocity mode Current mode Velocity control using armature voltage feedbackCurrent loop Current limitsTime dependent peak current limit Dynamic contouring of continuous and peak current limits Operation of the shunt regulator Short circuit protection Temperature protectionLoss of velocity feedback signal Protective functionsCurrent Command Monitor Input ISP Control Board Page Contact rating 0.5A, 200V, 10W Terminals of ISP Panel Version Mother Board terminals MBA-ISP/N GND Terminals for ISP mounted in 3U size ENCContact rating 0.5A, 200V, 10W Page MBA ISP/3UE Wiring Installation procedures MountingAC power supply Load inductance2Vdcmin Vdc 0.9Vdcmax ISP GND Wiring diagramsDo not ground GroundAC ISP ISP Control Connections Tachogenerator Feedback ISP Control Connections Armature Voltage Feedback Disable by Low Start Up ProceduresEnable by High ISP Control Board Converting the amplifier into current mode Selecting the reference signal gain See .1 for calculation of other values For Vtm Activating the loss of tacho protection velocity mode onlyLatch mode of the protective functions Velocity control using tachogenerator feedbackActivating the dynamic contouring of the current limits For ISP-X/65 For ISP-X/135IxR compensation Amplifier adjustment and diagnostics Balance adjustmentCurrent limit adjustment Adjustment of the IxR compensation Adjusting the motor speed velocity mode onlyResponse adjustment velocity mode only Typical velocity response waveforms ISP Rev 6/95 LED diagnostics Tables and Summaries Adjusting trimmersAppendix a Response adjustment current loop Fig. A-1 Typical current response waveforms ISP Rev 6/95 Velocity Torque Appendix B Current limits contour adjustmentDynamic contouring with armature voltage feedback ISP Rev 6/95 SP1 TOP View SP1 Side View SP1 Side View SP2 TOP View SP2 Side View SP2 Side View SP3 TOP View SP3 Side View SP3 Side View SP4 TOP View SP4 Side View SP4 Side View ISP Rack Mounting 8T and 15T TOP View ISP Rack Mounting 3U/8T Side View 128.7 Front Panel for ISP 3U/8T ISP Rack Mounting 3U/15T -SIDE View ISP Rack Mounting 3U/15T Side View Front Panel for ISP 3U/15T ISP Rack Mounting 3U/12T and 3U/19T TOP View ISP Rack Mounting 3U/12T -SIDE View ISP Rack Mounting 3U/12T Side View Front Panel for ISP 3U/12T ISP Rack Mounting 3U/19T -SIDE View ISP Rack Mounting 3U/19T Side View Front Panel for ISP 3U/19T Enclosure Mechanical Outline Europe List of Elmo Service Centers