Elmo ISP manual Current loop, Current limits, Time dependent peak current limit

Page 11

11

4.4Current loop

Current loop control is obtained by op amp U1/B (Current amplifier) and R7, C2 which form a lag-lead network for current loop. The standard amp is equipped with R7 (100Kohm) and C2 (0.01 æF) to get optimum current response for an average motor in this power range. These components are mounted in solderless terminals.

4.5Current limits

The servo amplifier can operate in the following voltage-current plane:

 

 

 

 

+V

 

 

 

-Ip

 

-Ic

 

 

Ic

 

Ip

Intermittent

 

Continuous

 

 

 

 

zone

 

zone

 

-V

 

 

 

 

Ic - Continuous current

Ip - Peak current

 

 

 

 

Fig. 4.1: Voltage-Current plane

 

Each amplifier is factory calibrated to have this shape of voltage-current operating area with rated values of continuous and peak current limits. In addition the peak current limit is time dependent as explained in 4.5.1.

4.5.1Time dependent peak current limit

The peak current is so designed that its duration is a function of the peak amplitude and the motor actual operating current before the peak demand. The maximum peak current is available for 1.6 second. The duration of Ip is given by:

ISP - Rev 6/95

Image 11
Contents Rev 6/95 ISP Rev 6/95 ELMO-WARRANTY Performance Read chapters Table of Contents Balance adjustment Current limit adjustment Protective functions Standard featuresDescription Type Designation Technical specificationsOperation of the servo control Inputs Velocity mode Current mode Velocity control using armature voltage feedbackTime dependent peak current limit Current loopCurrent limits Dynamic contouring of continuous and peak current limits Operation of the shunt regulator Short circuit protection Temperature protectionLoss of velocity feedback signal Protective functionsCurrent Command Monitor Input ISP Control Board Page Contact rating 0.5A, 200V, 10W Terminals of ISP Panel Version Mother Board terminals MBA-ISP/N GND Terminals for ISP mounted in 3U size ENCContact rating 0.5A, 200V, 10W Page MBA ISP/3UE Wiring Installation procedures Mounting2Vdcmin Vdc 0.9Vdcmax AC power supplyLoad inductance ISP GND Wiring diagramsDo not ground GroundAC ISP ISP Control Connections Tachogenerator Feedback ISP Control Connections Armature Voltage Feedback Disable by Low Start Up ProceduresEnable by High ISP Control Board See .1 for calculation of other values Converting the amplifier into current modeSelecting the reference signal gain For Vtm Activating the loss of tacho protection velocity mode onlyActivating the dynamic contouring of the current limits Latch mode of the protective functionsVelocity control using tachogenerator feedback IxR compensation For ISP-X/65For ISP-X/135 Current limit adjustment Amplifier adjustment and diagnosticsBalance adjustment Adjustment of the IxR compensation Adjusting the motor speed velocity mode onlyResponse adjustment velocity mode only Typical velocity response waveforms ISP Rev 6/95 LED diagnostics Tables and Summaries Adjusting trimmersAppendix a Response adjustment current loop Fig. A-1 Typical current response waveforms ISP Rev 6/95 Velocity Torque Appendix B Current limits contour adjustmentDynamic contouring with armature voltage feedback ISP Rev 6/95 SP1 TOP View SP1 Side View SP1 Side View SP2 TOP View SP2 Side View SP2 Side View SP3 TOP View SP3 Side View SP3 Side View SP4 TOP View SP4 Side View SP4 Side View ISP Rack Mounting 8T and 15T TOP View ISP Rack Mounting 3U/8T Side View 128.7 Front Panel for ISP 3U/8T ISP Rack Mounting 3U/15T -SIDE View ISP Rack Mounting 3U/15T Side View Front Panel for ISP 3U/15T ISP Rack Mounting 3U/12T and 3U/19T TOP View ISP Rack Mounting 3U/12T -SIDE View ISP Rack Mounting 3U/12T Side View Front Panel for ISP 3U/12T ISP Rack Mounting 3U/19T -SIDE View ISP Rack Mounting 3U/19T Side View Front Panel for ISP 3U/19T Enclosure Mechanical Outline Europe List of Elmo Service Centers