4.4Current loop
Current loop control is obtained by op amp U1/B (Current amplifier) and R7, C2 which form a
4.5Current limits
The servo amplifier can operate in the following
|
|
|
| +V |
|
|
|
|
|
| Ic |
| Ip | ||
Intermittent |
| Continuous |
|
|
|
| |
zone |
| zone |
|
|
|
| |
| Ic - Continuous current | Ip - Peak current |
| ||||
|
|
| Fig. 4.1: |
|
Each amplifier is factory calibrated to have this shape of
4.5.1Time dependent peak current limit
The peak current is so designed that its duration is a function of the peak amplitude and the motor actual operating current before the peak demand. The maximum peak current is available for 1.6 second. The duration of Ip is given by: