48

Continuous current limit contouring:

 

1

-

r1

R11

= 18.3 --------

(Kohm)

 

1

-

r2

 

 

R11

R10

= 36.6 -------------

(Kohm)

 

R11

+ 20r1

Peak current limit contouring:

 

1

-

s1

R13

= 18.3 --------

(Kohm)

 

1

-

s2

 

 

R13

R12

= 36.6 ------------

(Kohm)

 

R13

+ 20s1

Dynamic contouring with armature voltage feedback

-IxR compensation must be activated as in 7.3

-Connect the Back EMF (terminal H-16,R-18c,E-J2/7) to input 2 (terminal H-5,R- 28a,E-J2/8).

-Remove R31.

-Insert R2 = 470 Ohm

-Insert R9 = 301 Kohm

-Calculate and insert R14 as in 7.1.4.

ISP - Rev 6/95

Image 48
Contents Rev 6/95 ISP Rev 6/95 ELMO-WARRANTY Performance Read chapters Table of Contents Balance adjustment Current limit adjustment Standard features DescriptionProtective functions Technical specifications Type DesignationOperation of the servo control Inputs Velocity mode Velocity control using armature voltage feedback Current modeCurrent loop Current limitsTime dependent peak current limit Dynamic contouring of continuous and peak current limits Operation of the shunt regulator Temperature protection Loss of velocity feedback signalProtective functions Short circuit protectionCurrent Command Monitor Input ISP Control Board Page Contact rating 0.5A, 200V, 10W Terminals of ISP Panel Version Mother Board terminals MBA-ISP/N Terminals for ISP mounted in 3U size ENC GNDContact rating 0.5A, 200V, 10W Page MBA ISP/3UE Installation procedures Mounting WiringAC power supply Load inductance2Vdcmin Vdc 0.9Vdcmax Wiring diagrams ISP GNDGround Do not groundAC ISP ISP Control Connections Tachogenerator Feedback ISP Control Connections Armature Voltage Feedback Start Up Procedures Disable by LowEnable by High ISP Control Board Converting the amplifier into current mode Selecting the reference signal gainSee .1 for calculation of other values Activating the loss of tacho protection velocity mode only For VtmLatch mode of the protective functions Velocity control using tachogenerator feedbackActivating the dynamic contouring of the current limits For ISP-X/65 For ISP-X/135IxR compensation Amplifier adjustment and diagnostics Balance adjustmentCurrent limit adjustment Adjusting the motor speed velocity mode only Adjustment of the IxR compensationResponse adjustment velocity mode only Typical velocity response waveforms ISP Rev 6/95 Tables and Summaries Adjusting trimmers LED diagnostics Appendix a Response adjustment current loop Fig. A-1 Typical current response waveforms ISP Rev 6/95 Appendix B Current limits contour adjustment Velocity TorqueDynamic contouring with armature voltage feedback ISP Rev 6/95 SP1 TOP View SP1 Side View SP1 Side View SP2 TOP View SP2 Side View SP2 Side View SP3 TOP View SP3 Side View SP3 Side View SP4 TOP View SP4 Side View SP4 Side View ISP Rack Mounting 8T and 15T TOP View ISP Rack Mounting 3U/8T Side View 128.7 Front Panel for ISP 3U/8T ISP Rack Mounting 3U/15T -SIDE View ISP Rack Mounting 3U/15T Side View Front Panel for ISP 3U/15T ISP Rack Mounting 3U/12T and 3U/19T TOP View ISP Rack Mounting 3U/12T -SIDE View ISP Rack Mounting 3U/12T Side View Front Panel for ISP 3U/12T ISP Rack Mounting 3U/19T -SIDE View ISP Rack Mounting 3U/19T Side View Front Panel for ISP 3U/19T Enclosure Mechanical Outline List of Elmo Service Centers Europe