Appendix A - Response adjustment - current loop

In most applications it is not necessary to adjust the current loop to achieve the optimum response. When there are extreme electrical parameters in the armature circuit (inductance and resistance) the standard components values of 0.01æF for C2 and 100Kohm for R7 may not yield with the optimum response. The current loop should be optimized as follows:

-Turn the amplifier to a current amplifier by removing C1 and R6.

-Provide the amplifier with a bi-directional square wave current command (100- 200Hz, ñ2.0V waveform is often employed).

-Apply power to the amplifier, and monitor the load current either by a current probe or by the current monitor.

If the current response is not critically damped, use the following procedure

-Short circuit C2 with a short jumper wire.

-Replace R7 with a decade resistance box. Initially set the box resistance at 10Kohm.

-Apply the square wave test signal to the amplifier input.

-Apply power, and while monitoring the load current, gradually increase the value of the box resistance until optimum response a depicted in Fig A-1 is achieved.

-Substitute the closest standard value discrete resistor for R7 and remove the decade resistance box.

-Remove the shorting jumper across C2, and again check the response using the square wave test signal.

-If the previous step does not yield satisfactory results, if unacceptable overshooting has been noted, substitute a larger value than 0.01 æF; or, if the response is overdamped, substitute smaller value than 0.01 æF. Repetition of this procedure should yield an optimum choice for C2.

ISP - Rev 6/95

Image 45
Contents Rev 6/95 ISP Rev 6/95 ELMO-WARRANTY Performance Read chapters Table of Contents Balance adjustment Current limit adjustment Standard features DescriptionProtective functions Type Designation Technical specificationsOperation of the servo control Inputs Velocity mode Current mode Velocity control using armature voltage feedbackCurrent loop Current limitsTime dependent peak current limit Dynamic contouring of continuous and peak current limits Operation of the shunt regulator Loss of velocity feedback signal Temperature protectionProtective functions Short circuit protectionCurrent Command Monitor Input ISP Control Board Page Contact rating 0.5A, 200V, 10W Terminals of ISP Panel Version Mother Board terminals MBA-ISP/N GND Terminals for ISP mounted in 3U size ENCContact rating 0.5A, 200V, 10W Page MBA ISP/3UE Wiring Installation procedures MountingAC power supply Load inductance2Vdcmin Vdc 0.9Vdcmax ISP GND Wiring diagramsDo not ground GroundAC ISP ISP Control Connections Tachogenerator Feedback ISP Control Connections Armature Voltage Feedback Disable by Low Start Up ProceduresEnable by High ISP Control Board Converting the amplifier into current mode Selecting the reference signal gainSee .1 for calculation of other values For Vtm Activating the loss of tacho protection velocity mode onlyLatch mode of the protective functions Velocity control using tachogenerator feedbackActivating the dynamic contouring of the current limits For ISP-X/65 For ISP-X/135IxR compensation Amplifier adjustment and diagnostics Balance adjustmentCurrent limit adjustment Adjustment of the IxR compensation Adjusting the motor speed velocity mode only Response adjustment velocity mode only Typical velocity response waveforms ISP Rev 6/95 LED diagnostics Tables and Summaries Adjusting trimmersAppendix a Response adjustment current loop Fig. A-1 Typical current response waveforms ISP Rev 6/95 Velocity Torque Appendix B Current limits contour adjustmentDynamic contouring with armature voltage feedback ISP Rev 6/95 SP1 TOP View SP1 Side View SP1 Side View SP2 TOP View SP2 Side View SP2 Side View SP3 TOP View SP3 Side View SP3 Side View SP4 TOP View SP4 Side View SP4 Side View ISP Rack Mounting 8T and 15T TOP View ISP Rack Mounting 3U/8T Side View 128.7 Front Panel for ISP 3U/8T ISP Rack Mounting 3U/15T -SIDE View ISP Rack Mounting 3U/15T Side View Front Panel for ISP 3U/15T ISP Rack Mounting 3U/12T and 3U/19T TOP View ISP Rack Mounting 3U/12T -SIDE View ISP Rack Mounting 3U/12T Side View Front Panel for ISP 3U/12T ISP Rack Mounting 3U/19T -SIDE View ISP Rack Mounting 3U/19T Side View Front Panel for ISP 3U/19T Enclosure Mechanical Outline Europe List of Elmo Service Centers