Sony MZ-N10 service manual A n u a l, N u a l, Configuration of Test Mode, Manual Mode

Page 12

MZ-N10

Configuration of Test Mode

[Test Mode $Display Check Mode%] Press the > or [VOL +] key,

or press the [VOL +] key on the remote commander

[Manual Mode]

Press the x key

[Servo Adjustment]

[Audio Adjustment]

[Power Supply Adjustment]

[OP Alignment Adjustment] Press the . or [VOL --] key

[Overall Adjustment Mode]

Press the x key

[Electrical Offset Adjustment]

Power Supply Adjustment

Auto Item Feed

CD Overall Adjustment/

MO Overall Adjustment

Turn the jog dial (down),

or press the [DISPLAY] key on the remote commander

[Self-Diagnosis Result Display Mode]

Press the x key

Press the N or z REC . key,

or press the > key on the remote commander

[Sound Skip Check Result Display Mode]

Remote commander LCD display

000M a n u a l

Set LCD display

000

M a n u a l

3.During each test, the optical pick-up moves outward or in- ward while the > or . key is pressed for several sec- onds respectively.

4.Each test item is assigned with a 3-digit item number;

100th place is a major item, 10th place is a medium item, and unit place is a minor item.

The values adjusted in the test mode are written to the non- volatile memory (for the items where adjustment was made).

 

 

 

 

 

[VOL +] key: 100th place of item

[Major item switching]

number increase.

 

 

 

 

 

[VOL --]key: 100th place of item

 

 

key

 

x key

number decrease.

 

>

 

 

 

 

 

 

 

 

 

[VOL +] key: 10th place of item

[Medium

item switching]

number increase.

Press the x key

Press the [T MARK] key, or press the [DISPLAY] key on the remote commander for several

seconds (about 3 seconds)

[Key Check Mode]

The key check quits, or open the upper panel

Manual Mode

>key x key

[Minor item switching]

[VOL --]key: 10th place of item number decrease.

>key: Unit place of item number

increase.

.key: Unit place of item number decrease.

Mode to adjust or check the operation of the set by function. Normally, the adjustment in this mode is not executed. However, the Manual mode is used to clear the memory, power supply adjustment, and laser power check before performing automatic adjustments in the Overall Adjustment mode.

The manual mode consists of a major item, a medium item and a minor item.

The manual mode is divided into four groups of major items.

SERVO

: item number 000

- 500, 800 -

AUDIO

: item number 600

-

POWER

: item number 700

-

OP

: item number 900

-

A medium item divides a major item and is used to select func- tions.

In a minor item, adjustments or operation checks are performed.

• Transition method in manual mode

1.Set the test mode (see page 11).

2.Press the > key, [VOL +] key or [VOL +] key on the re- mote commander activates the manual mode where the LCD display as shown below.

[Adjusted value variation]

[VOL +] key: Increases the adjusted value of the 1st digit

[VOL --]key: Decreases the adjusted value of the 1st digit

[P MODE] key of

the remote commander: Increase the adjusted value of the 2nd digit

[SOUND] key of the remote commander: Decrease the adjusted value of the 2nd digit

[Adjusted value write]

Xkey or

key of the remote commander: When adjusted value is changed:

Adjusted value is written. When adjusted value is not changed:

That item is adjusted automatically.

[RAM monitor]

[T MARK] key or

[SOUND] key of the remote commander for several seconds

12

Image 12
Contents MZ-N10 ATRAC3 LP2/LP4On power sources Flexible Circuit Board RepairingPolarity of the plug Table of Contents Section Servicing Notes System requirementsRecorder Headphones/earphones with a remote control Section GeneralSection Disassembly Equipment can be removed using the following procedureBottom Panel Section, Jog Dial Section Upper Panel SectionMain Board Section MD Mechanism Deck MT-MZN10-181, Set ChassisOP Service Assy ABX-1R Gear SA, Gear SBHolder Assy Section Test Mode Setting Method of Test ModeOperation in Setting the Test Mode Releasing the Test ModeConfiguration of Test Mode Manual ModeTransition method in manual mode A n u a l011 C 6 8 S 0 F F J 0011 0 6 3 B 0 011 0 5 9 a 0Reset the Error Display Code L r O K ?R r C L R 000 P * * R 000000 FF 000 rFFRMC OK 000 JOG+000 JOG+OK 000 JOGReset ResNV CCResOK? 021 ResPower Supply Manual Adjustment 741 VC1 L742 VC1 H 743 VC2 Lo747 REG3L1 748 REG3L2749 REG3 H Vrec LVrec H 754 3.3upcChgV L ChgV HTP1907 REG3 TP1909 REG1 Power Supply Adjustment Auto Item Feed Configuration of power supply adjustment auto item feedAssy ADJ OKLaser LrefPw @HrefPw @ WrPwLo @Configuration of overall adjustment mode Adjusted values modifying procedure881 ###S 882 ###SAssy11 000 *** NGCD OK MO OKMO overall adjustment items Resume clear setting method Resume043 Res ResClrRewriting the Patch Data at Replacement of Main Board PreparationPre-check Rewriting the patch dataMZ-N10 Confirmation of contents of the patch data rewrited Removing the set How to get the application NVWriter for NV values rewriting Rewriting the NV valuesRewriting the NV values MZ-N10 MZ-N10 MZ-N10 043 Remaining charging time Number of times of fully chargingSection Diagrams Block DiagramWaveforms 4Vp-pPrinted Wiring Board Main Board Side a Uses unleaded solder Semiconductor LocationMain Board Side B Uses unleaded solder Main BoardSchematic Diagrams Main Board 1/4 See page 38 for Waveforms C513 270 ∝H TC7SZ126AFE IC Block Diagrams IC302 AN17020A-VBIC502 XC62HR2202MR IC503 XC62HR2502MR IC862 R2061K01-E2 IC951 SC901582EPR2 IC Pin Function Description Sens FmckXskh XsklFfclr XcsnvJoga JogbUosci UoscoSI3 SO3Xras XCSDVSS0 DVSS1FVDD0 FVSS0Msak Section Exploded Views KNOB, Balance White . . . REDBottom Panel Section US,CND,HK,KR,TW,E18,CHChassis Section 111 112 106 105 104 103MD Mechanism Deck Section MT-MZN10-181 152 153 151Main Electrical Parts List SectionMain CAP,CHIP Ceramic Resistor Switch 501 502 505504 503 507Memo Revision History Date Description of Revision