Sony MZ-N10 service manual ResNV CC, ResOK?, 021 Res, Reset, SetTmp @

Page 17

MZ-N10

SECTION 5

ELECTRICAL ADJUSTMENTS

Outline

In this set, automatic adjustment of CD and MO can be per- formed by entering the test mode.

However, before starting automatic adjustment, the memory clear, power supply adjustment, and laser power check must be performed in the manual mode.

A key having no particular description in the text, indicates a set key.

For the LCD display, the LCD on the remote commander is shown, but the contents of LCD display on the set are same.

NV Reset

Caution: The shipment data will be cleared without the adjusted values of the electrical offset adjustment and power sup- ply adjustment when the NV is reset.

• Setting method of NV reset

1.Select the manual mode of the test mode, and set item number 021 NV Reset (see page 12).

Remote commander LCD display

Precautions for Adjustment

1.Adjustment must be done in the test mode only. After adjusting, release the test mode.

2.Use the following tools and measuring instruments.

• Test CD disc

TDYS-1

 

(Part No. : 4-963-646-01)

SONY MO disc available on the market

Digital voltmeter

• Laser power meter LPM-8001

(Part No. : J-2501-046-A)

AC adaptor (6V) and USB cradle

Personal computer

USB cable

Regulated dc power supply (two sets)

Thermometer (using the Temperature Correction)

3.Unless specified otherwise, use AC adaptor (6V) and USB cradle.

4.Switch position

HOLD switch ............................................... ON

Adjustment Sequence

1.

NV Reset (item number: 021)

 

 

(EEPROM clear)

Manual Mode

 

 

 

r

 

2.

 

Manual Mode

Temperature Correction (item number: 015)

 

r

 

3.

Power Supply Manual Adjustment

 

 

r

Manual Mode

 

4.

Laser Power Check and Adjustment

 

 

r

 

 

 

5.

Adjustment required before Overall

 

Manual Mode

 

Adjustment

 

 

 

r

 

6.

CD Overall Adjustment (item number: 031)

 

 

 

r

Overall Mode

7.

 

 

MO Overall Adjustment (item number: 034)

 

 

r

 

8.

RESUME Clear (item number 043)

 

Manual Mode

 

r

 

 

9.Rewriting the Patch Data

(at replacement of the MAIN board) r

10.Rewriting the NV values

Note: “2. Temperature Correction” and “3. Power Supply Manual Adjust-

ment” can be performed continuously with pressing the [VOL --]key or the [P MODE] key on the remote commander in the overall adjustment mode.

021 ResNV CC

2. Press the X key.

Remote commander LCD display

021ResOK?

3.Press the X key once more.

Remote commander LCD display

021Res***

NV reset (after several seconds)

021Reset!

4.Press the x key to quit the manual mode, and return to the test mode (display check mode).

Temperature Correction

• Adjustment method of temperature correction

1.Select the manual mode of test mode, and set the item number 015 (see page 12).

Remote commander LCD display

015 SetTmp @**

**: Adjusted value

2.Measure the ambient temperature.

3.Adjust with [VOL +], [VOL --]key so that the adjusted value

(hexadecimal value) becomes the ambient temperature. (Initial value: 19h = 25 °C, Adjusting range: 80h to 7fh (–128 °C to +127 °C)

4.Press the X key to write the adjusted value.

5.Press the x key to quit the manual mode, and return to the test mode (display check mode).

Note : Power supply adjustment auto item feed mode (see page 22 ) is available to perform the temperature correction and power supply adjustment without entering the manual mode.

17

Image 17
Contents ATRAC3 LP2/LP4 MZ-N10Polarity of the plug On power sourcesFlexible Circuit Board Repairing Table of Contents System requirements Section Servicing NotesSection General Recorder Headphones/earphones with a remote controlEquipment can be removed using the following procedure Section DisassemblyUpper Panel Section Bottom Panel Section, Jog Dial SectionMD Mechanism Deck MT-MZN10-181, Set Chassis Main Board SectionGear SA, Gear SB OP Service Assy ABX-1RHolder Assy Setting Method of Test Mode Section Test ModeOperation in Setting the Test Mode Releasing the Test ModeManual Mode Configuration of Test ModeTransition method in manual mode A n u a lF F J 0 011 C 6 8 S 0011 0 6 3 B 0 011 0 5 9 a 0R r C L R Reset the Error Display CodeL r O K ? 000 000 P * * R000 FF 000 rFF000 JOG+ RMC OK000 JOG+OK 000 JOGResNV CC ResetResOK? 021 Res741 VC1 L Power Supply Manual Adjustment742 VC1 H 743 VC2 Lo748 REG3L2 747 REG3L1749 REG3 H Vrec L754 3.3upc Vrec HChgV L ChgV HTP1907 REG3 TP1909 REG1 Configuration of power supply adjustment auto item feed Power Supply Adjustment Auto Item FeedAssy ADJ OKLrefPw @ LaserHrefPw @ WrPwLo @Adjusted values modifying procedure Configuration of overall adjustment mode881 ###S 882 ###S000 *** NG Assy11CD OK MO OKMO overall adjustment items Resume Resume clear setting method043 Res ResClrPreparation Rewriting the Patch Data at Replacement of Main BoardPre-check Rewriting the patch dataMZ-N10 Confirmation of contents of the patch data rewrited Removing the set Rewriting the NV values How to get the application NVWriter for NV values rewritingRewriting the NV values MZ-N10 MZ-N10 MZ-N10 Remaining charging time Number of times of fully charging 043Block Diagram Section Diagrams4Vp-p WaveformsSemiconductor Location Printed Wiring Board Main Board Side a Uses unleaded solderMain Board Main Board Side B Uses unleaded solderSchematic Diagrams Main Board 1/4 See page 38 for Waveforms C513 270 ∝H TC7SZ126AFE IC302 AN17020A-VB IC Block DiagramsIC502 XC62HR2202MR IC503 XC62HR2502MR IC862 R2061K01-E2 IC951 SC901582EPR2 IC Pin Function Description Fmck SensXskh XsklXcsnv FfclrJoga JogbUosco UosciSI3 SO3XCS XrasDVSS0 DVSS1Msak FVDD0FVSS0 KNOB, Balance White . . . RED Section Exploded ViewsUS,CND,HK,KR,TW,E18,CH Bottom Panel Section111 112 106 105 104 103 Chassis Section152 153 151 MD Mechanism Deck Section MT-MZN10-181Section Main Electrical Parts ListMain CAP,CHIP Ceramic Resistor Switch 505 501 502504 503 507Memo Date Description of Revision Revision History