MZ-N10
SECTION 4
TEST MODE
Outline
•This set provides the Overall adjustment mode that allows CD and MO discs to be automatically adjusted when in the test mode. In this overall adjustment mode, the disc is discriminate between CD and MO, and each adjustment is automatically executed in order. If a fault is found, the system displays its location. Also, the manual mode allows each individual adjustment to be auto- matically adjusted.
•Operation in the test mode is performed with the set. A key having no particular description in the text, indicates a set key.
•For the LCD display, the LCD on the remote commander is shown, but the contents of LCD display on the set are same. (Both displays may be displayed.)
Setting Method of Test Mode
There are three different methods to set the test mode:
1Short SL803 (TEST) on the MAIN board with a solder bridge (connect pin <zx. of IC801 to the ground) and turn on the power.
– MAIN Board (Side B) –
IC801
TP1829
R838
C815
1 - 6 8 6 - 3 4 7 -
SL803 (TEST)
3In case of setting the test mode by keys on the set and remote commander:
In the normal mode, turn on the [HOLD] switch on the set. While pressing the x key on the set, press the keys on the remote commander with the following order:
>t > t . t . t > t
.t > t . t t
Note: If electrical adjustment (CD and MO overall adjustment) has not been finished completely, “ERROR” is displayed on LCDs of the set and the remote commander.
Operation in Setting the Test Mode
•When the test mode becomes active, first the display check mode is selected.
•Other mode can be selected from the display check mode.
•When the test mode is set, the LCD repeats the following dis- play.
Remote commander LCD display
All lit
All off
Microcomputer
versionV1.100 display
Set LCD display
All lit
All off
Microcomputer | 001 |
|
version | Ver 1.100 |
display |
|
2In case of setting the test mode only by keys on the set:
In the normal mode, turn on the [HOLD] switch. While press-
ing the [GROUP] key press the following order:
>t > t . t . t > t
. t > t . t X t X
•When the X key is pressed and hold down, the display at that time is held so that display can be checked.
Releasing the Test Mode
For test mode set with the method 1:
Turn off the power and open the solder bridge on SL803 (TEST) on the MAIN board.
Note: Remove the solders completely. Remaining could be shorted with the chassis, etc.
For test mode set with the method 2 or 3:
Turn off the power.
11