MZ-N10
Charging Information Clear of
Function of recording the charging information is equipped for design confirmation.
There are two informations only for
•Remaining charging time
•The number of times of fully charging
Initialization of the information is required at replacement of built- in rechargeable battery since it is pequliar to the
Perform the initialization as the following procedure.
1.Select the manual mode of the test mode, and set item number 043 (Resume clear and time set clear).
Remote commander LCD display
043 Resume 00
adjusted value
2.Adjust with the [VOL +] key so that the adjusted value be-
comes 02, and press the X key or key on the remote commander.
Remote commander LCD display
043 **** 02
3. Resume clear is completed when the following display appears.
Remote commander LCD display
043ResClr
4.Press the mode).
x
key to return to the test mode (display check
36