Ericsson LBI-38965B installation manual Example, Configuration Tips

Page 35

INSTALLATION

LBI-38965

EXAMPLE:

Assume that the file CAL.DAT has the following two site entries: System Manger site 2 is connected to port 3 on the distribution panel, and System Manager site 10 is connected to port 6 on the distribution panel.

SITE.02.PASSWD

SITE02

 

SITE.02.IP

147.117.37.10

#Terminal server IP address

SITE.02.PORT

5002

#TCP port_no used for site 2

SITE.10.PASSWD

SITE10

 

SITE.10.IP

147.117.37.10

 

SITE.10.PORT

5010

#TCP port_no used for site 10

Inserting the information below would configure the terminal server for the values shown above.

Server>> change port 3 access remote

Server>> change port 3 type softcopy

Server>> change port 3 autobaud disabled

Server>> change port 3 speed 19200

Server>> change service PORT_3 5002 port 3 telnet disabled

Server>> change port 3 queuing disabled

Server>> change port 3 flow control disabled

Server>> change port 6 access remote

Server>> change port 6 type softcopy

Server>> change port 6 autobaud disabled

Server>> change port 6 speed 19200

Server>> change service PORT_6 5010 port 6 telnet disabled

Server>> change port 6 queuing disabled

Server>> change port 6 flow control disabled

After completing the configuration, reconnect the Ethernet LAN connection to the terminal server. If a second terminal server is installed, repeat the procedure above.

Configuration Tips

If all 16 ports of a terminal server are needed for System Manager interface, first configure 15 of them using a “dumb” terminal connected to port 1. Port 1 (configuration port) may then be re-assigned to a remote port, accessible via a telnet connection. Telnet into the terminal server on the OVERRIDE port number, and reconfigure port 1 as required. Refer to the Emulex Terminal Server user’s manual for additional information on server configuration via a telnet connection.

The up arrow on a VT100 can be used to recall commands to the terminal server, allowing the user to reissue the same command to each port on the server by only changing port_no.

NOTE

The push button switch (marked default) on the front of the Emulex P2516 terminal server will erase all configuration information in the terminal server and return it to the factory default state. Do not use this switch to reset the terminal server. Cycle power or issue the “Initialize server” command from the server configuration port to restart the terminal server.

35

Image 35
Contents Ericssonz LBI-38965 Table of Contents Table of Contents BCU/CAL Architecture IntroductionCall Types Supported BCU Functional DescriptionCAL Functional Description Introduction Physical Description and Compatibility Physical SpecificationsTVME147 CPU BCU/CAL ArchitectureCPU Backwards Compatibility CompatibilityBCU Operational Specifications SpecificationsCommon BCU and CAL Operational Specifications Billing Architecture BCU Operation Overview Billing ArchitectureGrouping Calls Group Billing ModeRF Channel Usage Air Time ConversationsFile Name ContentsUnit Data Default DataOperator Functions Database ElementsCall Processing CDR Output CDR Processing ErrorsCall Processing CDR ProcessingProtocol Supported CAL Operational SpecificationsSystem Manager Interface CAL Operation Overview Additional Product Features Network File SystemHardware Installation InstallationDistribution Media Software InstallationUsage Installation DisketteMeaning ROUTES.DAT Configuration FileParameter IP.DAT File ParametersDirectory clientip EXPORTS.DAT File Parameters EXPORTS.DAT Configuration FileCAL.DAT File Parameters CAL.DAT Configuration FilePrerequisites Initial InstallationInstallation Installation User Information Access Level Default System AccountsLogin PasswordUser Information Entering bcs invokes the BCS program PrerequisiteSystem Disk Booting User Information Invoke the BCS program Software UpgradesProper System Shutdown # access CAL Terminal Server ConfigurationExample Configuration TipsThis page intentionally left blank Appendix a Edacs Billing CDR Format Record Encoding OverviewBilling by Conversation Billing for Multiple SitesCDR Radix-64 Digit Record LayoutSINGLE-SITE Calls MULTIPLE-SITE CallsTable A.1 Call Detail Record Field Descriptions MOBILE-TO-LAND Telephone Interconnect CallsDescription Call Type DefinitionsCall Type Hex Decimal Table A.2 Call TypesDescription Valid with Rec. Type A0-FF Table A.3 Call Type Bit Field Definitions Call Type Bit FieldsCDR File Topics Page Appendix B Physical Configuration Details Jumper Settings Figure B.1 Tvme 147SA1 Single-Board Computer Figure B.2 Tvme 712/M Transition Module Figure B.4 fv5310 Main Board Figure B.5 fv5310 Mezzanine Card Scsi Connector Pwr Function Connector DB-25F Signal NameCable Pinouts Table B.1 WANServer PortTable B.2 WANServer Port Table B.3 WANServer Port Table B.4 WANServer Port DB-25M Connector M/W BCU/CAL Port Signal Name Table B.5 BCU/CAL Hdlc Loopback Cable SpecificationFigure B.9 CAL Terminal Server to Distribution Panel Cable Figure B.10 CAL 32-Port Configuration Computer Terminal Appendix C Fault Tolerance Redundant Operation Figure C.1 Edacs Billing Fault Tolerant Architecture