Ericsson LBI-38965B Record Layout, SINGLE-SITE Calls, MULTIPLE-SITE Calls, CDR Radix-64 Digit

Page 39

EDACS BILLING FORMAT

LBI-38965

The following table defines the ASCII characters used in the CDR radix-64 sequence number field, and their associated decimal values.

CDR Radix-64 Digit

0123456789

ABCDEFGHIJ

KLMNOPQRST

UVWXYZabcd

efghijklmn

opqrstuvwx

yz#$

5. RECORD LAYOUT

5.1. SINGLE-SITE CALLS

Decimal Equivalent

0 to 9

10 to 19

20 to 29

30 to 39

40 to 49

50 to 59

60 to 63

The following diagram shows the layout of the fields in a basic CDR for a single-site call. The top row shows the field name and number, the middle row shows the subfield name and letter, if applicable, and the bottom row shows the byte offset within the record.

1.Record 2. Node ID No. Type

 

 

a. System

b. Node

0

1

2

3

4

5

3. Record ID No.

6

7

8

9

4. Start Date

 

 

 

 

 

 

5. Start Time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

a. Year

 

 

b. Month

c. Day

 

a. Hour

b. Minute

c. Second

10

11

12

13

14

15

16

 

17

18

19

20

21

22

23

6.Call Type

7. Caller ID No.

8. Callee ID No.

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

9. Elapsed Time

10. Accumulated Air Time 11. No. of Channel Assignments

12. No. of 13. Site of Origin Sites

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

a. No.

 

b. Channel Map

 

 

 

46

47

48

49

50

51

52

53

54

55

56

57

58

59

60

61

62

 

63

64

65

66

67

68

69

Figure A.1 - Call Detail Record, Single-Site Call

5.2. MULTIPLE-SITE CALLS

A CDR may have 0 to n additional fields added beginning at byte offset 70, where n = No. of Sites - 1. The format of the additional fields is identical to the Site of Origin field (field 13) and is shown in the diagram below. The offset, x, of the first byte in each additional field is calculated as x = 62 + (8n).

13 +n. Additional Site n

 

 

 

 

 

 

 

 

 

 

 

 

 

a. No.

 

b. Channel Map

 

 

 

x

 

x+1

x+2

x+3

 

x+4

x+5

x+6

x+7

Figure A.2 - Call Detail Record, Additional Site Field

A-3

Image 39
Contents Ericssonz LBI-38965 Table of Contents Table of Contents BCU/CAL Architecture IntroductionBCU Functional Description CAL Functional DescriptionCall Types Supported Introduction Physical Description and Compatibility Physical SpecificationsTVME147 CPU BCU/CAL ArchitectureCPU Backwards Compatibility CompatibilitySpecifications Common BCU and CAL Operational SpecificationsBCU Operational Specifications Billing Architecture BCU Operation Overview Billing ArchitectureGrouping Calls Group Billing ModeRF Channel Usage Air Time ConversationsFile Name ContentsUnit Data Default DataOperator Functions Database ElementsCall Processing CDR Output CDR Processing ErrorsCall Processing CDR ProcessingCAL Operational Specifications System Manager InterfaceProtocol Supported CAL Operation Overview Additional Product Features Network File SystemHardware Installation InstallationDistribution Media Software InstallationUsage Installation DisketteMeaning ROUTES.DAT Configuration FileParameter IP.DAT File ParametersDirectory clientip EXPORTS.DAT File Parameters EXPORTS.DAT Configuration FileCAL.DAT File Parameters CAL.DAT Configuration FilePrerequisites Initial InstallationInstallation Installation User Information Access Level Default System AccountsLogin PasswordUser Information Entering bcs invokes the BCS program PrerequisiteSystem Disk Booting Software Upgrades Proper System ShutdownUser Information Invoke the BCS program # access CAL Terminal Server ConfigurationExample Configuration TipsThis page intentionally left blank Appendix a Edacs Billing CDR Format Record Encoding OverviewBilling by Conversation Billing for Multiple SitesCDR Radix-64 Digit Record LayoutSINGLE-SITE Calls MULTIPLE-SITE CallsTable A.1 Call Detail Record Field Descriptions MOBILE-TO-LAND Telephone Interconnect CallsDescription Call Type DefinitionsCall Type Hex Decimal Table A.2 Call TypesDescription Valid with Rec. Type A0-FF Table A.3 Call Type Bit Field Definitions Call Type Bit FieldsCDR File Topics Page Appendix B Physical Configuration Details Jumper Settings Figure B.1 Tvme 147SA1 Single-Board Computer Figure B.2 Tvme 712/M Transition Module Figure B.4 fv5310 Main Board Figure B.5 fv5310 Mezzanine Card Scsi Connector Pwr Function Connector DB-25F Signal NameCable Pinouts Table B.1 WANServer PortTable B.2 WANServer Port Table B.3 WANServer Port Table B.4 WANServer Port DB-25M Connector M/W BCU/CAL Port Signal Name Table B.5 BCU/CAL Hdlc Loopback Cable SpecificationFigure B.9 CAL Terminal Server to Distribution Panel Cable Figure B.10 CAL 32-Port Configuration Computer Terminal Appendix C Fault Tolerance Redundant Operation Figure C.1 Edacs Billing Fault Tolerant Architecture