Ericsson LBI-38965B Prerequisite, User Information Entering bcs invokes the BCS program

Page 31

INSTALLATION

LBI-38965

These parameters are defined using the BCU/CAL Configuration Service (BCS) program. BCS is discussed in detail in LBI-38967. The following example is provided for reference to get the BCU set up and running as quickly as possible.

PREREQUISITE

1.Obtain the IMC slot number of the NIM and PIM modules, if any.

2.If not already logged into the BCU/CAL, log in under the "root" account as previously discussed. Enter the following commands at the indicated prompts.

USER INFORMATION: Entering "bcs" invokes the BCS program.

pSH+> bcs

Welcome to the BCU-CAL Configuration Service (BCS)

System Administrator privilege acknowledged.

USER INFORMATION: Entering "show system" displays the default system parameters that were initialized during the initial software installation.

BCS> show system

Default unit pseudo hangtime = 10

Default group pseudo hangtime = 10

Default group billing mode = Bill callee

Data call pseudo hangtime = 10

Data call billing = On

Phone digits mandatory = Off

CDR maximum file records = 1024

CDR sequence wrapping = On

Offload time = 00:00:00

Tape logging = Off

CDR archive(s) lifetime = 7

IMC time synchronization = Off

System ID = 0

Node ID = 0

NIM slot = 0

PIM slot = 0

USER ACTION: To define the IMC NIM slot, execute the following command. This example assumes that the NIM occupies slot 32. The actual value should reflect the end user's IMC configuration. If the IMC does not have a NIM, disregard this command.

BCS> set system /nim = 32

USER ACTION: To define the IMC PIM slot (for Jessica), execute the following command. This example assumes that the PIM occupies slot 16. The actual value should reflect the end user's IMC configuration. If the IMC does not have a PIM, skip this command.

BCS> set system /pim = 16

31

Image 31
Contents Ericssonz LBI-38965 Table of Contents Table of Contents BCU/CAL Architecture IntroductionCAL Functional Description BCU Functional DescriptionCall Types Supported Introduction Physical Description and Compatibility Physical SpecificationsTVME147 CPU BCU/CAL ArchitectureCPU Backwards Compatibility CompatibilityCommon BCU and CAL Operational Specifications SpecificationsBCU Operational Specifications Billing Architecture BCU Operation Overview Billing ArchitectureGrouping Calls Group Billing ModeRF Channel Usage Air Time ConversationsFile Name ContentsUnit Data Default DataOperator Functions Database ElementsCall Processing CDR Output CDR Processing ErrorsCall Processing CDR ProcessingSystem Manager Interface CAL Operational SpecificationsProtocol Supported CAL Operation Overview Additional Product Features Network File SystemHardware Installation InstallationDistribution Media Software InstallationUsage Installation DisketteMeaning ROUTES.DAT Configuration FileParameter IP.DAT File ParametersDirectory clientip EXPORTS.DAT File Parameters EXPORTS.DAT Configuration FileCAL.DAT File Parameters CAL.DAT Configuration FilePrerequisites Initial InstallationInstallation Installation User Information Access Level Default System AccountsLogin PasswordUser Information Entering bcs invokes the BCS program PrerequisiteSystem Disk Booting Proper System Shutdown Software UpgradesUser Information Invoke the BCS program # access CAL Terminal Server ConfigurationExample Configuration TipsThis page intentionally left blank Appendix a Edacs Billing CDR Format Record Encoding OverviewBilling by Conversation Billing for Multiple SitesCDR Radix-64 Digit Record LayoutSINGLE-SITE Calls MULTIPLE-SITE CallsTable A.1 Call Detail Record Field Descriptions MOBILE-TO-LAND Telephone Interconnect CallsDescription Call Type DefinitionsCall Type Hex Decimal Table A.2 Call TypesDescription Valid with Rec. Type A0-FF Table A.3 Call Type Bit Field Definitions Call Type Bit FieldsCDR File Topics Page Appendix B Physical Configuration Details Jumper Settings Figure B.1 Tvme 147SA1 Single-Board Computer Figure B.2 Tvme 712/M Transition Module Figure B.4 fv5310 Main Board Figure B.5 fv5310 Mezzanine Card Scsi Connector Pwr Function Connector DB-25F Signal NameCable Pinouts Table B.1 WANServer PortTable B.2 WANServer Port Table B.3 WANServer Port Table B.4 WANServer Port DB-25M Connector M/W BCU/CAL Port Signal Name Table B.5 BCU/CAL Hdlc Loopback Cable SpecificationFigure B.9 CAL Terminal Server to Distribution Panel Cable Figure B.10 CAL 32-Port Configuration Computer Terminal Appendix C Fault Tolerance Redundant Operation Figure C.1 Edacs Billing Fault Tolerant Architecture