Ericsson LBI-38965B installation manual MOBILE-TO-LAND Telephone Interconnect Calls

Page 40

LBI-38965

EDACS BILLING FORMAT

5.3. MOBILE-TO-LAND TELEPHONE INTERCONNECT CALLS

A CDR for a mobile-to-land telephone interconnect call will have an additional field beginning at byte offset 70. This field contains the digits dialed by the caller. A mobile-to-land call never involves multiple sites, so the PSTN Telephone Number field is never combined with the Additional Site fields described in the preceding section.

14. PSTN Telephone No.

70

71

72

73

74

75

76

77

78

79

80

81

82

83

84

85

86

87

88

89

90

91

 

101

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

..

 

Figure A.3 - Call Detail Record, PSTN Telephone Number Field

5.4. CALCULATING THE NUMBER OF BYTES IN A CDR

Note that the final linefeed character which terminates the record is not shown in these diagrams. The actual number of bytes in a CDR is calculated by adding 2 to the offset of the final byte. For example, a group call involving 4 sites contains 3 additional site fields, beginning at offset 70 and ending at offset 93 (from the formulae above). The actual length of the record, including the linefeed character, is thus 95 bytes.

5.5. CDR FIELD DESCRIPTIONS

Table A.1 contains detailed descriptions of each of the CDR fields.

Table A.1 - Call Detail Record Field Descriptions

No.

1.

2.

a.

b.

3.

4.

a.

b.

c.

5.

a.

b.

c.

6.

7.

8.

9.

10.

11.

12.

Name

Record Type

Node ID No.

System

Node

Record ID No.

Start Date

Year

Month

Day

Start Time

Hour

Minute

Second

Call Type

Caller ID No.

Callee ID No.

Elapsed Time

Accumulated Air

Time

No. of Channel

Assignments

Number of Sites

Size

2

4

2

2

4

8

4

2

2

6

2

2

2

2

10

10

4

5

5

2

Format

Hex

Hex

Hex

Radix-64

Decimal

Decimal

Decimal

Decimal

Decimal

Decimal

Hex

Decimal

Decimal

Hex

Hex

Hex

Decimal

Range/Values

00 - FF

00 - FF

00 - FF

1970-2038

01 - 12

01 - 31

00 - 23

00 - 59

00 - 59

00 - FF (See Table A.2)

0000000000 -

9999999999

0000000000 -

9999999999

0000 - FFFF

00000 - FFFFF

00000 - FFFFF

01 - 32

Description

Defines the type of record. 00 = Mobile to Mobile

01 = Mobile to Land Interconnect

02 = Illegal

03 = Land to Mobile Interconnect

04 = Data

05- FF = Reserved

Unique identification number for the EDACS node where the call activity in this CDR occurred. User configurable.

System ID Number (Multiple nodes) Node ID Number (Multiple sites)

Unique identifier for the Call Detail Record.

The date when the call was initiated.

The time of day when the call was initiated. Hours are in military format.

The type of call as defined in Table A.2. Indicates whether call is group or individual, whether to bill the caller or the callee, etc.

For Record Types 00 and 01, this field contains the Logical ID (LID) of the caller. For Record Type 03, the field contains the Interconnect Line number.

For Record Types 00 and 03, this field contains the Logical ID (LID) of an individual callee, or the Group ID (GID) of a call group. (The Call Type field indicates individual or group call.) For Record Type 01, the field contains the Interconnect Line number.

The duration of the call in seconds

The number of seconds of actual air time used on all sites on the local node for this call. Does not include air time on site 32 which is a remote node.

The number of times a channel assignment occurred on a site within the local node for this call.

The number of sites on the local node which participated in this call.

A-4

Image 40
Contents Ericssonz LBI-38965 Table of Contents Table of Contents Introduction BCU/CAL ArchitectureCAL Functional Description BCU Functional DescriptionCall Types Supported Introduction Physical Specifications Physical Description and CompatibilityBCU/CAL Architecture TVME147 CPUCPU Compatibility Backwards CompatibilityCommon BCU and CAL Operational Specifications SpecificationsBCU Operational Specifications Billing Architecture Billing Architecture BCU Operation OverviewGroup Billing Mode RF Channel Usage Air TimeConversations Grouping CallsContents File NameDefault Data Operator FunctionsDatabase Elements Unit DataCDR Processing Errors Call ProcessingCDR Processing Call Processing CDR OutputSystem Manager Interface CAL Operational SpecificationsProtocol Supported Additional Product Features Network File System CAL Operation OverviewInstallation Hardware InstallationSoftware Installation Distribution MediaInstallation Diskette UsageROUTES.DAT Configuration File ParameterIP.DAT File Parameters MeaningEXPORTS.DAT Configuration File Directory clientip EXPORTS.DAT File ParametersCAL.DAT Configuration File CAL.DAT File ParametersInitial Installation PrerequisitesInstallation Installation User Information Default System Accounts LoginPassword Access LevelPrerequisite User Information Entering bcs invokes the BCS programSystem Disk Booting Proper System Shutdown Software UpgradesUser Information Invoke the BCS program CAL Terminal Server Configuration # accessConfiguration Tips ExampleThis page intentionally left blank Appendix a Edacs Billing CDR Format Overview Billing by ConversationBilling for Multiple Sites Record EncodingRecord Layout SINGLE-SITE CallsMULTIPLE-SITE Calls CDR Radix-64 DigitMOBILE-TO-LAND Telephone Interconnect Calls Table A.1 Call Detail Record Field DescriptionsCall Type Definitions Call Type Hex DecimalTable A.2 Call Types DescriptionDescription Valid with Rec. Type A0-FF Call Type Bit Fields Table A.3 Call Type Bit Field DefinitionsCDR File Topics Page Appendix B Physical Configuration Details Jumper Settings Figure B.1 Tvme 147SA1 Single-Board Computer Figure B.2 Tvme 712/M Transition Module Figure B.4 fv5310 Main Board Figure B.5 fv5310 Mezzanine Card Scsi Connector Pwr Connector DB-25F Signal Name Cable PinoutsTable B.1 WANServer Port FunctionTable B.2 WANServer Port Table B.3 WANServer Port Table B.4 WANServer Port Table B.5 BCU/CAL Hdlc Loopback Cable Specification DB-25M Connector M/W BCU/CAL Port Signal NameFigure B.9 CAL Terminal Server to Distribution Panel Cable Figure B.10 CAL 32-Port Configuration Computer Terminal Appendix C Fault Tolerance Figure C.1 Edacs Billing Fault Tolerant Architecture Redundant Operation