E1 - Reverse Elevation Pot
Step 1. Calibrate Elevation
Calibrate the elevation as outlined in the System Calibration Procedure in below step.
Error 1
Enter engineer mode of
“MANUAL
CALIBRATION”
screen
Check the “P13 ELV DIRECTION” screen whether set to “Yes”
Enter the “P4 ELEVATION
MINIMUM” screen
whether parameter set is
30 2
Enter the “P5
ELEVATION
MAXIMUM ” screen
whether parameter set is
240 5
Set to “Yes” | AUTO- | |
Calibration | ||
|
AUTO-
Calibration
AUTO-
Calibration
Step 2. CORRECTIVE ACTION
1.Ensure correct signal is being sent to interface board (MCB) by pressing elevation up/down keys by observing elevation LED’s correctly corresponding to correct elevation keys pressed (please refer the 29 page) . If failure occurs for this step check console cable and then the interface board (MCB).
2.Check failed elevation motor, interface board, console cable with a known good console.
32