Miele T9800HRT service manual Calibrate Elevation, Corrective Action

Page 32

E1 - Reverse Elevation Pot

Step 1. Calibrate Elevation

Calibrate the elevation as outlined in the System Calibration Procedure in below step.

Error 1

Enter engineer mode of

“MANUAL

CALIBRATION”

screen

Check the “P13 ELV DIRECTION” screen whether set to “Yes”

Enter the “P4 ELEVATION

MINIMUM” screen

whether parameter set is

30 2

Enter the “P5

ELEVATION

MAXIMUM ” screen

whether parameter set is

240 5

Set to “Yes”

AUTO-

Calibration

 

AUTO-

Calibration

AUTO-

Calibration

Step 2. CORRECTIVE ACTION

1.Ensure correct signal is being sent to interface board (MCB) by pressing elevation up/down keys by observing elevation LED’s correctly corresponding to correct elevation keys pressed (please refer the 29 page) . If failure occurs for this step check console cable and then the interface board (MCB).

2.Check failed elevation motor, interface board, console cable with a known good console.

32

Image 32
Contents Vision T9800HRT Table of Contents Section Maintenance Procedure Maintenance Check List Tensioning the Belt Procedure Frequency Every 1 months Running BeltDrive Belt Procedure Frequency Every 1 monthClean the Grooves Procedure Frequency Every 3 months ProcedureSection Wiring Diagram Instruction T9800TM87 MCB Wiringfor 110V Motor wireT9800TM87 MCB Wiring Definition of PIN JP1Elevation cable6pin/AMP-350762-4J2 console cable 202T9800TM87 Console Wiring Safety Pull Switch J15 CsafeT8900TM87 Console Wiring Definition of PIN J13 T9800TM87 Electrical block diagram for T9800TM87 Wiring Diagram Instruction for T9800TM87 Electrical block diagram for T9800TM87 Wiring Diagram Instruction for Section Console Functional Flow Diagram Operating T9800 KEY Behale Function Set the data/function StepConfiguration Engineering Mode MenuManual Calibration System Tests Maintenance Section MCB LED Instructions AC FAN LED DescriptionSection Troubleshootings T9800 Console Error code Calibrate Elevation Corrective ActionE2 Elevation Out Of Range E3 Elevation Stall Auto Calibration StepE6 Runaway Belt Error E7 Speed Stall Error E9 Speed Range Error Page Corrective Action Procedures Speed Issues Corrective Action Procedures Belt Drive Issues Corrective Action Procedures Speed Control Issues Perform steps in order listed until problem resolvedCorrective Action Procedures Speed Calibration Issue Operation Errors