Miele T9800HRT service manual Corrective Action Procedures Speed Issues

Page 40

CORRECTIVE ACTION PROCEDURES – Speed Issues

Speed Feedback Issue

Enter Magnet Count

screen

N

Magnet count = treadmill # of magnets

Y

Manually rotate belt and check

for only 1 speed pulse on interface board per magnet (check all magnets)

N

OK?

Adjust magnet count to match number of magnets

N

No pules for either magnet

Y

Re-run test

N

Pulse

only one

magnet

Y

Perform steps in order listed until problem resolved.

1. .Check connections

2. .Check magnet orientation (correct poles)

3. .Check sensor mounting

4. .Replace sensor w/ known good sensor

5. .Replace interface PCB with known good PCB

N

Multiple pulse per magnet

Y

Enter effective diameter screen of firmware setup

Setup effective

diameter as described in system calibration section of this document

Perform steps in order listed until problem resolved.

1.Check connections

2.Check magnet orientation (correct poles)

3.Check sensor mounting

4.Replace sensor w/ known good sensor

5.Replace interface PCB with known good PCB

Perform steps in order listed until problem resolved.

1.Check magnet orientation (correct poles)

2.Check sensor mounting

3.Replace sensor w/ known good sensor

Perform steps in order listed until problem resolved.

1.If reed type sensor replace with Hall type sensor or correctly orient sensor.

2.Check connections

3.Check sensor mounting

4.Replace sensor w/ known good sensor

Y

Problem

Fixed

N

Perform steps in order listed until problem resolved.

1.Check connections

2.Check magnet orientation (correct poles)

3.Check sensor mounting

4.Replace sensor w/ known good sensor

5.Replace interface PCB with known good PCB

6.Replace console PCB with know good PCB

Re-calibrate

system

Done

40

Image 40
Contents Vision T9800HRT Table of Contents Section Maintenance Procedure Maintenance Check List Tensioning the Belt Procedure Frequency Every 1 months Running BeltDrive Belt Procedure Frequency Every 1 monthClean the Grooves Procedure Frequency Every 3 months ProcedureSection Wiring Diagram Instruction T9800TM87 MCB Wiringfor 110V Motor wireT9800TM87 MCB Wiring Definition of PIN JP1Elevation cable6pin/AMP-350762-4J2 console cable 202T9800TM87 Console Wiring Safety Pull Switch J15 CsafeT8900TM87 Console Wiring Definition of PIN J13 T9800TM87 Electrical block diagram for T9800TM87 Wiring Diagram Instruction for T9800TM87 Electrical block diagram for T9800TM87 Wiring Diagram Instruction for Section Console Functional Flow Diagram Operating T9800 KEY Behale Function Set the data/function StepConfiguration Engineering Mode MenuManual Calibration System Tests Maintenance Section MCB LED Instructions AC FAN LED DescriptionSection Troubleshootings T9800 Console Error code Calibrate Elevation Corrective ActionE2 Elevation Out Of Range E3 Elevation Stall Auto Calibration StepE6 Runaway Belt Error E7 Speed Stall Error E9 Speed Range Error Page Corrective Action Procedures Speed Issues Corrective Action Procedures Belt Drive Issues Corrective Action Procedures Speed Control Issues Perform steps in order listed until problem resolvedCorrective Action Procedures Speed Calibration Issue Operation Errors