MANUAL CALIBRATION

Address

Description

Default

Minimum

Maximum

 

 

 

Value

Value

Value

 

 

 

 

 

 

 

P0 PWM MIN

PWM value at min speed (0.5

34

1

 

111

SPD

mph/0.8kph)

 

 

 

 

 

 

 

 

 

 

 

P1 PWM 1/2

PWM value at 1/2 max speed (6.0

176

110

251

MAX

mph/10.0kph)

 

 

 

 

 

 

 

 

 

 

 

P2 PWM MAX

PWM value at max speed (12.0

341

249

486

SPD

mph/20.0kph)

 

 

 

 

 

 

 

 

 

 

 

P4 ELEVATION

Value at zero or minimum elevation

40

27

 

71

MIN

 

 

 

 

 

 

 

 

 

 

 

 

 

P5 ELEVATION

Value at maximum elevation

218

71

 

228

MAX

 

 

 

 

 

 

 

 

 

 

 

 

 

P13 ELV

 

 

YES

 

 

 

DIRECTION

 

 

 

 

 

 

 

 

 

 

 

 

 

P19 MAGNET

 

 

26

1

 

48

COUNT

 

 

 

 

 

 

 

 

 

 

 

 

 

P20 EFF

 

 

67.8

 

 

 

DIAMETER

 

 

 

 

 

 

 

 

 

 

 

 

 

P21 PWM

 

 

30

1

 

~

START SPD

 

 

 

 

 

 

 

 

 

 

 

 

 

P29 RAMP TIME

 

 

30

12

 

40

 

 

 

 

 

 

 

EXIT

Exits mode

 

 

 

 

Remarks:

 

 

 

 

 

 

Do not change the product below parameter , or it may cause malfunction.

 

 

 

 

 

 

 

 

Address

 

Default Value

 

 

 

 

 

 

 

 

 

 

P13 ELV DIRECTION

 

YES

 

 

 

 

 

 

 

 

 

 

 

P19 MAGNET COUNT

 

26

 

 

 

 

 

 

 

 

 

 

 

P20 EFF DIAMETER

 

67.8

 

 

 

 

 

 

 

 

 

 

 

P29 RAMP TIME

 

30

 

 

 

 

 

 

 

 

 

 

24

Image 24
Contents Vision T9800HRT Table of Contents Section Maintenance Procedure Maintenance Check List Tensioning the Belt Procedure Frequency Every 1 months Running BeltDrive Belt Procedure Frequency Every 1 monthClean the Grooves Procedure Frequency Every 3 months ProcedureSection Wiring Diagram Instruction T9800TM87 MCB Wiringfor 110V Motor wireT9800TM87 MCB Wiring Definition of PIN JP1Elevation cable6pin/AMP-350762-4J2 console cable 202T9800TM87 Console Wiring Safety Pull Switch J15 CsafeT8900TM87 Console Wiring Definition of PIN J13 T9800TM87 Electrical block diagram for T9800TM87 Wiring Diagram Instruction for T9800TM87 Electrical block diagram for T9800TM87 Wiring Diagram Instruction for Section Console Functional Flow Diagram Operating T9800 KEY Behale Function Set the data/function StepConfiguration Engineering Mode MenuManual Calibration System Tests Maintenance Section MCB LED Instructions AC FAN LED DescriptionSection Troubleshootings T9800 Console Error code Calibrate Elevation Corrective ActionE2 Elevation Out Of Range E3 Elevation Stall Auto Calibration StepE6 Runaway Belt Error E7 Speed Stall Error E9 Speed Range Error Page Corrective Action Procedures Speed Issues Corrective Action Procedures Belt Drive Issues Corrective Action Procedures Speed Control Issues Perform steps in order listed until problem resolvedCorrective Action Procedures Speed Calibration Issue Operation Errors