Miele T9800HRT service manual Corrective Action Procedures Speed Calibration Issue

Page 43

CORRECTIVE ACTION PROCEDURES – Speed Calibration Issue

Speed Calibration Issue

Run auto calibration (firmware setup screen)

Auto calibration

Y

Done

passed

 

 

N

Start PWM max test (firmware setup screen), wait minimum 20 seconds or until sped stabilizes

Measure speed and compare to value

displayed in time window

OK

N

Check speed feedback

 

 

issue

 

 

Y

 

 

Check speed control issue

 

 

43

Image 43
Contents Vision T9800HRT Table of Contents Section Maintenance Procedure Maintenance Check List Frequency Every 1 months Running Belt Tensioning the Belt ProcedureDrive Belt Frequency Every 1 month ProcedureFrequency Every 3 months Procedure Clean the Grooves ProcedureSection Wiring Diagram Instruction Motor wire T9800TM87 MCB Wiringfor 110VJP1Elevation cable6pin/AMP-350762-4 T9800TM87 MCB Wiring Definition of PIN202 J2 console cableSafety Pull Switch J15 Csafe T9800TM87 Console WiringT8900TM87 Console Wiring Definition of PIN J13 T9800TM87 Electrical block diagram for T9800TM87 Wiring Diagram Instruction for T9800TM87 Electrical block diagram for T9800TM87 Wiring Diagram Instruction for Section Console Functional Flow Diagram Operating T9800 Set the data/function Step KEY Behale FunctionEngineering Mode Menu ConfigurationManual Calibration System Tests Maintenance Section MCB LED Instructions AC FAN Description LEDSection Troubleshootings T9800 Console Error code Corrective Action Calibrate ElevationE2 Elevation Out Of Range E3 Elevation Stall Step Auto CalibrationE6 Runaway Belt Error E7 Speed Stall Error E9 Speed Range Error Page Corrective Action Procedures Speed Issues Corrective Action Procedures Belt Drive Issues Perform steps in order listed until problem resolved Corrective Action Procedures Speed Control IssuesCorrective Action Procedures Speed Calibration Issue Operation Errors