Miele T9800HRT service manual Configuration, Engineering Mode Menu

Page 23

Engineering Mode Menu

CONFIGURATION

SYSTEM TESTS

AUTO-CALIBRATION

MANUAL CALIBRATION

MAINTENANCE

SOFTWARE VERSION

EXIT

CONFIGURATION

Address

Description

Default

Minimum

Maximum

 

 

Value

Value

Value

 

 

 

 

 

P6 T9800HRT

English,0.5-12 Mph,15% Incline for USA

 

 

 

 

 

 

 

 

P6 T9800HRT INT

Metric,0.8-20 Kph,15%Incline for ID

 

 

 

 

English,0.5-12 Mph,15% Incline for ID

 

 

 

 

 

 

 

 

P6 T9800S

English,0.5-12mph,15% Incline for USA

 

 

 

 

 

 

 

 

P24 UNITS

English/Metric

 

 

 

 

 

 

 

 

P7 MAXIMUM

 

99

5

99

TIME

 

 

 

 

 

 

 

 

 

P22 DEFAULT

 

30

5

99

TIME

 

 

 

 

 

 

 

 

 

P23 PAUSE TIME

 

0:20

0:05

10:00

 

 

 

 

 

P27 DEFAULT AGE

 

40

15

99

 

 

 

 

 

P8 DEFAULT

English

150

80

400

WEIGHT

Metric

68

36

181

 

 

 

 

 

P15 SCROLL

 

3

1

5

SPEED

 

 

 

 

 

 

 

 

 

P30 Maximum Speed

English

12.0 20.0

 

 

 

Metric

 

 

 

 

 

 

 

 

P14 ELEVATION

 

ON

 

 

ERRS—OFF

 

 

 

 

 

 

 

 

 

Reset Novram

 

 

 

 

 

 

 

 

 

EXIT

Exits mode

 

 

 

 

 

 

 

 

 

 

 

 

23

Image 23
Contents Vision T9800HRT Table of Contents Section Maintenance Procedure Maintenance Check List Frequency Every 1 months Running Belt Tensioning the Belt ProcedureDrive Belt Frequency Every 1 month ProcedureFrequency Every 3 months Procedure Clean the Grooves ProcedureSection Wiring Diagram Instruction Motor wire T9800TM87 MCB Wiringfor 110VJP1Elevation cable6pin/AMP-350762-4 T9800TM87 MCB Wiring Definition of PIN202 J2 console cableSafety Pull Switch J15 Csafe T9800TM87 Console WiringT8900TM87 Console Wiring Definition of PIN J13 T9800TM87 Electrical block diagram for T9800TM87 Wiring Diagram Instruction for T9800TM87 Electrical block diagram for T9800TM87 Wiring Diagram Instruction for Section Console Functional Flow Diagram Operating T9800 Set the data/function Step KEY Behale FunctionEngineering Mode Menu ConfigurationManual Calibration System Tests Maintenance Section MCB LED Instructions AC FAN Description LEDSection Troubleshootings T9800 Console Error code Corrective Action Calibrate ElevationE2 Elevation Out Of Range E3 Elevation Stall Step Auto CalibrationE6 Runaway Belt Error E7 Speed Stall Error E9 Speed Range Error Page Corrective Action Procedures Speed Issues Corrective Action Procedures Belt Drive Issues Perform steps in order listed until problem resolved Corrective Action Procedures Speed Control IssuesCorrective Action Procedures Speed Calibration Issue Operation Errors