E3 – Elevation Stall
Step 1. Please refer the below PROBLEM IDENTIFICATION Step.
E3 Error
Check the “P13 ELV DIRECTION” screen whether set to “Yes”
Set to “Yes” | AUTO- | |
Calibration | ||
|
Enter Hardware Test Screen
Run Elevation Up And Down
Treadmill | N |
| Y |
|
| ||
moves up or |
| Motor | Waiting the Elevation |
| Motor to cool | ||
down? |
| Overheated? | |
|
| ||
Y |
| N |
|
| Motor Movement Issue |
| |
|
|
| |
Feedback | Y |
|
|
|
| ||
Changes |
|
| |
|
|
| |
Elevation |
|
|
|
N |
|
|
|
Position Feedback Problem
Step 2. CORRECTIVE ACTION
1.Allow elevation motor to cool.
2.Check the failed system with a known good console cable. If fixed then repair/replace the console cables.
3.Check the failed system with a known good elevation motor. If problem fixed then repair/replace the elevation motor.
4.Check the failed system with a known good interface board (MCB). If problem fixed then repair/replace the interface board (MCB).
5.Check the failed system with a known good console board with current software. If | |
the problem is fixed then repair/replace the console. | 34 |
|