Miele T9800HRT service manual Operation Errors

Page 44

OPERATION ERRORS

E16 – Stuck key error

OVERVIEW

If a key press is detected for more than 45 seconds a stuck key error is flagged. This error is primarily caused by a faulty keypad but could be caused by other issues (object on the keypad).

CORRECTIVE ACTION

Reset system power. If error re-occurs replace the keypad with a known good keypad. If error still occurs replace console PCB with known good console PCB.

E18 – Safety switch test failure

OVERVIEW

If the actual speed exceeds limit set for safety switch test a safety switch test failure error occurs..

CORRECTIVE ACTION

Re-calibrate system as listed in system calibration section of this document and re-run safety switch test. If system still fails safety switch test run speed feedback issue and speed control issue tests in the corrective action procedures section of this document.

E19 – NOVRAM Failure

OVERVIEW

If the values stored in non-volatile memory are out of limits or do not match the safety check value stored in non-volatile memory a NOVRAM failure occurs. The system attempts to re- initialize the non-volatile memory three times and if the NOVRAM check fails all three attempts a NOVRAM failure error (E19) is called.

CORRECTIVE ACTION

An E-19 error indicates the NOVRAM has critically failed and needs to be replaced. If an E19 error occurs the console should be reprogrammed with the current software version and the power should be toggled. If this does not clear the E-19 error the console PCB will need to be returned to DCI for repair.

44

Image 44
Contents Vision T9800HRT Table of Contents Section Maintenance Procedure Maintenance Check List Tensioning the Belt Procedure Frequency Every 1 months Running BeltDrive Belt Procedure Frequency Every 1 monthClean the Grooves Procedure Frequency Every 3 months ProcedureSection Wiring Diagram Instruction T9800TM87 MCB Wiringfor 110V Motor wireT9800TM87 MCB Wiring Definition of PIN JP1Elevation cable6pin/AMP-350762-4J2 console cable 202T9800TM87 Console Wiring Safety Pull Switch J15 CsafeT8900TM87 Console Wiring Definition of PIN J13 T9800TM87 Electrical block diagram for T9800TM87 Wiring Diagram Instruction for T9800TM87 Electrical block diagram for T9800TM87 Wiring Diagram Instruction for Section Console Functional Flow Diagram Operating T9800 KEY Behale Function Set the data/function StepConfiguration Engineering Mode MenuManual Calibration System Tests Maintenance Section MCB LED Instructions AC FAN LED DescriptionSection Troubleshootings T9800 Console Error code Calibrate Elevation Corrective ActionE2 Elevation Out Of Range E3 Elevation Stall Auto Calibration StepE6 Runaway Belt Error E7 Speed Stall Error E9 Speed Range Error Page Corrective Action Procedures Speed Issues Corrective Action Procedures Belt Drive Issues Corrective Action Procedures Speed Control Issues Perform steps in order listed until problem resolvedCorrective Action Procedures Speed Calibration Issue Operation Errors