E5 – Over-speed Error
OVERVIEW
If the actual speed from the speed sensor exceeds the system maximum speed by a limit (currently 2 MPH) an
Step 1. AUTO CALIBRATION
Error 5
Enter engineer mode of
“AUTO
CALIBRATION”
Please will start Key held for 3 seconds to auto calibration
Measured speed < | Speed feedback |
14 MPH & | |
displayed speed > | issue |
14MPH
Speed control issue
Speed Feedback Issues – See speed feedback issue trouble shooting guide in the CORRECTIVE ACTION PROCEDURES – Speed Issues section of this document. Speed Control Issues – See speed control issue trouble shooting guide in the CORRECTIVE ACTION PROCEDURES – Speed Issues section of this document.
Step 2 :
1.Record when parameter information with error (please refer the 25 page of P1 / P2 / P3 place) .
2.Remove Power!!! Carefully check all connections.
3.Check interface board (MCB) with the speed sensor ensure contact are correct and fix.
4.If AUTO CALIBRATION can't finish, please take speed sensor to be close to magnet and AUTO CALIBRATION again.
5.If repeat over speed errors occur remove the treadmill from service.
35