Miele T9800HRT service manual Auto Calibration, Step

Page 35

E5 – Over-speed Error

OVERVIEW

If the actual speed from the speed sensor exceeds the system maximum speed by a limit (currently 2 MPH) an over-speed error occurs (E5).

Step 1. AUTO CALIBRATION

AUTO-Calibration the as outlined in the System Calibration Procedure in below step.

Error 5

Enter engineer mode of

“AUTO

CALIBRATION”

Please will start Key held for 3 seconds to auto calibration

Measured speed <

Speed feedback

14 MPH &

displayed speed >

issue

14MPH

Speed control issue

Speed Feedback Issues – See speed feedback issue trouble shooting guide in the CORRECTIVE ACTION PROCEDURES – Speed Issues section of this document. Speed Control Issues – See speed control issue trouble shooting guide in the CORRECTIVE ACTION PROCEDURES – Speed Issues section of this document.

Step 2 :

1.Record when parameter information with error (please refer the 25 page of P1 / P2 / P3 place) .

2.Remove Power!!! Carefully check all connections.

3.Check interface board (MCB) with the speed sensor ensure contact are correct and fix.

4.If AUTO CALIBRATION can't finish, please take speed sensor to be close to magnet and AUTO CALIBRATION again.

5.If repeat over speed errors occur remove the treadmill from service.

35

Image 35
Contents Vision T9800HRT Table of Contents Section Maintenance Procedure Maintenance Check List Frequency Every 1 months Running Belt Tensioning the Belt ProcedureDrive Belt Frequency Every 1 month ProcedureFrequency Every 3 months Procedure Clean the Grooves ProcedureSection Wiring Diagram Instruction Motor wire T9800TM87 MCB Wiringfor 110VJP1Elevation cable6pin/AMP-350762-4 T9800TM87 MCB Wiring Definition of PIN202 J2 console cableSafety Pull Switch J15 Csafe T9800TM87 Console WiringT8900TM87 Console Wiring Definition of PIN J13 T9800TM87 Electrical block diagram for T9800TM87 Wiring Diagram Instruction for T9800TM87 Electrical block diagram for T9800TM87 Wiring Diagram Instruction for Section Console Functional Flow Diagram Operating T9800 Set the data/function Step KEY Behale FunctionEngineering Mode Menu ConfigurationManual Calibration System Tests Maintenance Section MCB LED Instructions AC FAN Description LEDSection Troubleshootings T9800 Console Error code Corrective Action Calibrate ElevationE2 Elevation Out Of Range E3 Elevation Stall Step Auto CalibrationE6 Runaway Belt Error E7 Speed Stall Error E9 Speed Range Error Page Corrective Action Procedures Speed Issues Corrective Action Procedures Belt Drive Issues Perform steps in order listed until problem resolved Corrective Action Procedures Speed Control IssuesCorrective Action Procedures Speed Calibration Issue Operation Errors