SYSTEM TESTS
HARDWARE TEST
DISPLAY TEST
KEYBOARD TEST
SAFETY SWITCH TEST
IO TEST
ELEVATION
EXIT
MANUAL CALIBRATION
Address | Description | Default | Minimum | Maximum |
|
| Value | Value | Value |
|
|
|
|
|
P0 PWM MIN SPD | PWM value at min speed (0.5 mph/0.8kph) | 34 | 1 | 111 |
|
|
|
|
|
P1 PWM 1/2 MAX | PWM value at 1/2 max speed (6.0 mph/10.0kph) | 176 | 110 | 251 |
|
|
|
|
|
P2 PWM MAX SPD | PWM value at max speed (12.0 mph/20.0kph) | 341 | 249 | 486 |
|
|
|
|
|
P4 ELEVATION | Value at zero or minimum elevation | 40 | 27 | 71 |
MIN |
|
|
|
|
|
|
|
|
|
P5 ELEVATION | Value at maximum elevation | 218 | 71 | 228 |
MAX |
|
|
|
|
|
|
|
|
|
P13 ELV |
| YES |
|
|
DIRECTION |
|
|
|
|
|
|
|
|
|
P19 MAGNET |
| 26 | 1 | 48 |
COUNT |
|
|
|
|
|
|
|
|
|
P20 EFF |
| 67.8 341 |
|
|
DIAMETER |
|
|
|
|
|
|
|
|
|
P21 PWM START |
| 30 | 1 | ~ |
SPD |
|
|
|
|
|
|
|
|
|
P29 RAMP TIME |
| 30 | 12 | 40 |
|
|
|
|
|
EXIT | Exits mode |
|
|
|
|
|
|
|
|