Miele T9800HRT service manual E9 Speed Range Error

Page 38

E9 – Speed Range Error

OVERVIEW

During normal run time operation the value stored during auto calibration is used to initially set the speed (e.g. target speed = 12 MPH, PWM ticks = Maximum PWM = 363). Once the speed stabilized the actual speed is monitored and if different than the target speed the PWM value is adjusted until the actual speed matches the target speed. If the PWM value is changed by more than the amount of ticks required to change 0.8 MPH and the actual speed does not match the target speed then an E9 error is flagged. This error indicates the motor controller system is unable to maintain the target speed.

E9 Error

Before cycling power inspect the

motor controller for error

MotorY controller error

N

Start PWM ½ MAX test

Measure speed and compare to value displayed in time window

Record the error

code from the

motor controller

Check for free movement of belt roller movement

Cycle Power

Run auto

calibration

Done

OK

N

Perform steps outlined in speed

 

 

feedback issue

 

 

 

Y

 

Run Auto Calibration

 

 

 

 

 

Error

N

Perform steps outlined in

 

Gone

 

speed control issue

Y

 

 

Done

 

38

Image 38
Contents Vision T9800HRT Table of Contents Section Maintenance Procedure Maintenance Check List Tensioning the Belt Procedure Frequency Every 1 months Running BeltDrive Belt Procedure Frequency Every 1 monthClean the Grooves Procedure Frequency Every 3 months ProcedureSection Wiring Diagram Instruction T9800TM87 MCB Wiringfor 110V Motor wireT9800TM87 MCB Wiring Definition of PIN JP1Elevation cable6pin/AMP-350762-4J2 console cable 202T9800TM87 Console Wiring Safety Pull Switch J15 CsafeT8900TM87 Console Wiring Definition of PIN J13 T9800TM87 Electrical block diagram for T9800TM87 Wiring Diagram Instruction for T9800TM87 Electrical block diagram for T9800TM87 Wiring Diagram Instruction for Section Console Functional Flow Diagram Operating T9800 KEY Behale Function Set the data/function StepConfiguration Engineering Mode MenuManual Calibration System Tests Maintenance Section MCB LED Instructions AC FAN LED DescriptionSection Troubleshootings T9800 Console Error code Calibrate Elevation Corrective ActionE2 Elevation Out Of Range E3 Elevation Stall Auto Calibration StepE6 Runaway Belt Error E7 Speed Stall Error E9 Speed Range Error Page Corrective Action Procedures Speed Issues Corrective Action Procedures Belt Drive Issues Corrective Action Procedures Speed Control Issues Perform steps in order listed until problem resolvedCorrective Action Procedures Speed Calibration Issue Operation Errors