Bodyguard T360 Access to Diagnostics menu, Nvram Test, Eprom test, Keypad Test, Display Test

Page 25

5ComputerComputer Diagnosticsi s

Access to “Diagnostics” menu

To determine the condition of the various electrical and mechanical components, you will need to enter into the DIAGNOSTICS menu as follows:

1.Turn power OFF.

2.Simultaneously hold down the speed INCREASE and DECREASE keys and turn power ON.

3.Release the speed INCREASE and DECREASE keys once entered into the Diagnostics menu.

4.Press JustGoTM/ENTER to access Diagnostic items.

When you access the Diagnostics menu, you will notice the following message: “TXXX VERSION”

The message above indicates the version of the computer software installed in your computer display monitor. This information is helpful in diagnosing certain computer related conditions. Keep in mind that the version number may change depending on the model number of your T360 – T560 treadmill.

The T360 – T560 treadmills allow you to perform the following tests :

NVRAM TEST

HEART RATE TEST

SAFETY KEY TEST

EPROM TEST

BELT ALIGNMENT

ERROR LOG

KEYPAD TEST

MOTOR CHECK

CURRENT TEST

DISPLAY TEST

ELEVATION CALIBRATION

SPEED SENSOR TEST

BEEPER TEST

STATISTICS

MAINTENANCE

To perform any one of the above procedures, press the Speed INCREASE or DECREASE keys to select the one you want and press the JustGoTM/ENTER key to accept.

NVRAM Test

The NVRAM (Non-Volatile Random Access Memory) test will not erase all stored information such as user identification, and all saved programs. The NVRAM is a computer chip that saves information even when the treadmill has been turned off.

1.In the Diagnostics menu, select the “NVRAM TEST” and accept it by pressing the JustGoTM/ ENTER key.

2.Press the JustGo™/ENTER key to start the NVRAM test. The NVRAM test will perform automatically.

EPROM test

The EPROM test allows you to determine if the program stored in the EPROM chip is intact.

1.In the Diagnostics menu, select the ‘‘EPROM TEST’’ and accept it by pressing the JustGoTM/ ENTER key. The EPROM TEST will perform automatically.

The display will show ‘‘EPROM IS OK’’ if the EPROM is intact and it will display a “CHECKSUM” code (for Bodyguard® internal use only).

The display will show ‘‘EPROM IS NOT OK’’. This means the EPROM might be damaged.

Keypad Test

The keypad test allows you to verify that each key is responding when pressed.

1.Press each key one at a time and verify the confirmed response on the screen. Example, pressing the Elevation INCREASE key will cause the screen to display “ELEVATION INCREASE” indicating that the key press was recognized.

2.Press the CLEAR/STOP and JustGoTM/ENTER keys simultaneously to terminate the keypad test.

Display Test

The display test allows you to verify that each display light is properly working. If you notice that one or more areas on the screen do not light up during an exercise, you should perform this test.

1.In the Diagnostics menu, select the “DISPLAY TEST” and accept it by pressing the JustGoTM/ ENTER key.

2.Now the display will illuminate a certain way. To proceed to the next display patterns, press any key.

25

Image 25 Contents
T360 T560 Contents For Your Personal Safety Impotant Safety NoticeKnow Your Heart Rate Electrical InformationResponsibility of the User T360 T560 Limited WarrantyGetting to know the T360 T560 Computer display Monitor T360T360--T5T560Keys Pausing During an Exercise Scanning FeatureSaving an Exercise custom programs Language Feature Access to Settings MenuViewing Exercise Parameters Fitness Networking Cardio Theater, Fit LinxxWeight Unit Feature Distance Unit FeatureWarm Up and Cool Down Feature Beeper Feature Heart Rate Control Options FeatureHeart Rate Access Options Feature User Identification Feature Time, Distance or Calories FeatureTable of minimum and maximum values Activate UserEdit User Reset StatisticsView Statistics Delete UserSpeed Limits Edit Text FeaturePause Time Big Number OptionMax Duration Heart Rate Recovery16 Add/Remove Program Learn ProgramProgram Levels Saving Option On or OffJustGoTM Program Cardiovascular Program Manual ProgramInterval Program Random Program Hill Climb Program Walk ProgramTrack Program Speed Run ProgramRunner’s Interval Program Gerkin Protocol Program Required wireless chest strapHeart Rate Access Feature Requires wireless chest strap Using Contact Heart RateHow to Use Heart Rate Access Memory & Learn ProgramsChanging Your Target Heart Rate in a Program Usingsi a Heart Rate Receiveri rTroubleshooting Check List Table Possible Chest Strap Heart Rate ProblemsPossible Contact Heart Rate Problems Nvram Test Access to Diagnostics menuEprom test Keypad TestHeart Rate Test Beeper testBelt Alignment Motor Check Safety Key testElevation Calibration StatisticsMaintenance Error logCurrent test Speed Sensor testBelt and Running Deck Running Belt General CareLubricant application Deck SurfaceProblem Possible CAUSE/SOLUTION Quick Troubleshooting Check ListProblem Cause / Solution Error CodesThank You for Purchasing a Bodyguard T360 T560 International Safety requirements North AmericaInterference limits requirements North America CanadaMade in Canada