Bodyguard T360, T560 manual Quick Troubleshooting Check List, Problem Possible CAUSE/SOLUTION

Page 31

Quick Troubleshooting Check List

If you experience a problem during the normal operation of the T360 – T560, use the following troubleshooting table below. If you are unfamiliar or uncertain with basic diagnostic maintenance procedures, contact your Authorized Bodyguard® Dealer for diagnostics or repair of your T360 – T560.

Table 3

PROBLEM

POSSIBLE CAUSE/SOLUTION

• Computer will not light

• Unit is not plugged in. – Plug unit in.

up when power

• Power cord. – Check that power cord is functional; replace if necessary.

is turned ON.

• Circuit breaker. – Reset the breaker.

 

 

• Damaged motor circuit board. – Contact your Bodyguard® Dealer.

 

• The belt is over tensioned. – Perform Belt Alignment.

 

• The wires are not connected. – Remove the cover and connect the wires properly.

 

 

• Belt doesn’t turn.

• Magnetic key is not in place. – Insert the magnetic key.

 

 

• Elevation does not

• It is not calibrated. – Perform Elevation Calibration.

respond properly.

• The wire is not connected on the motor circuit board. –

 

 

Connect the elevation wire to the circuit board.

 

 

• Motor drive does not

• It is not calibrated. – Perform Motor Check.

respond properly.

• The wire is not connected on the motor circuit board. –

 

 

Motor wiring harness needs to be connected to the lower board.

 

 

• Motor turns backwards.

• The wires are reversed on the circuit drive. –

 

Contact your Bodyguard® Dealer.

• Computer key(s) not

• Keypad may be damaged by liquid penetrating through the seal. –

responding to touch,

Contact your Bodyguard® Dealer.

or sticking.

• Excessive amount of cleaning solution used. –

 

 

Use mild cleanser on damp cloth only when cleaning console and unit.

 

 

• Squeaking noise from

• Poly V-belt slipping. – Contact your Bodyguard® Dealer.

the motor.

• Motor brush noise excessive. – Contact your Bodyguard® Dealer.

• Belt tracks left

• Uneven floor. – Move the treadmill to an even floor.

and right.

• Rear roller not adjusted for sloped floor. –

 

 

The rear roller needs to be adjusted. Perform Belt Alignment.

 

 

• Speed is not constant or

• The drive motor is not calibrated. – Perform Motor Check.

seems too fast or slow.

• The tension on the motor drive is too excessive. –

 

 

Remove tension on the running belt. Perform Belt Alignment.

 

 

• Can’t get out at the end

• Elevation is not calibrated. – Perform Elevation Calibration.

of a program.

 

 

 

• Error log

• See table 4

 

 

31

Image 31
Contents T360 T560 Contents For Your Personal Safety Impotant Safety NoticeKnow Your Heart Rate Electrical InformationResponsibility of the User T360 T560 Limited WarrantyGetting to know the T360 T560 Computer display Monitor T360T360--T5T560Keys Pausing During an Exercise Scanning FeatureSaving an Exercise custom programs Fitness Networking Cardio Theater, Fit Linxx Access to Settings MenuLanguage Feature Viewing Exercise ParametersWeight Unit Feature Distance Unit FeatureWarm Up and Cool Down Feature Beeper Feature Heart Rate Control Options FeatureHeart Rate Access Options Feature Activate User Time, Distance or Calories FeatureUser Identification Feature Table of minimum and maximum valuesDelete User Reset StatisticsEdit User View StatisticsBig Number Option Edit Text FeatureSpeed Limits Pause TimeLearn Program Heart Rate RecoveryMax Duration 16 Add/Remove ProgramProgram Levels Saving Option On or OffJustGoTM Program Cardiovascular Program Manual ProgramInterval Program Random Program Hill Climb Program Walk ProgramTrack Program Speed Run ProgramRunner’s Interval Program Gerkin Protocol Program Required wireless chest strapMemory & Learn Programs Using Contact Heart RateHeart Rate Access Feature Requires wireless chest strap How to Use Heart Rate AccessChanging Your Target Heart Rate in a Program Usingsi a Heart Rate Receiveri rTroubleshooting Check List Table Possible Chest Strap Heart Rate ProblemsPossible Contact Heart Rate Problems Keypad Test Access to Diagnostics menuNvram Test Eprom testHeart Rate Test Beeper testBelt Alignment Statistics Safety Key testMotor Check Elevation CalibrationSpeed Sensor test Error logMaintenance Current testBelt and Running Deck Running Belt General CareLubricant application Deck SurfaceProblem Possible CAUSE/SOLUTION Quick Troubleshooting Check ListProblem Cause / Solution Error CodesThank You for Purchasing a Bodyguard T360 T560 Canada Safety requirements North AmericaInternational Interference limits requirements North AmericaMade in Canada