Bodyguard T360 Runner’s Interval Program, Gerkin Protocol Program Required wireless chest strap

Page 21

Runner’s Interval Program

The Runner’s Interval program is made for serious runners who want to simulate track workouts and create any workout they choose.

The program enables to select interval distance, number of repeats, Pace, Recovery Time and Recovery Pace wanted.

The parameters values are:

Interval distance: 200, 400, 600, 800, 1000, 1200, 1400 or 1600 meters

Number of repeats: 1 to 20

Pace: number of min. for 1 mile or number of min. for 1 kilometer

Recovery Time: 20 sec. to 20 min.

Recovery Pace: number of min. for 1 mile or number of min. for 1 kilometer

The Recovery Time will count down. The last 3 seconds of the recovery time will appear on the display and an audible beep will indicate the start of the next interval.

The program will start with a recovery segment, so that you are not starting from a dead stop.

The program will display an oval track of 400 meters that will show your progression on the track.

Example: 8 x 400’s meters @ 5:15 min. Pace with a 1 min. 30 sec. Recovery Time at 15:00 min. Pace.

To select the Runner’s Interval Program:

1.Press the other programs key.

2.Press the DECREASE key to select Runner’s Interval Program. Press ENTER key to accept.

3.Select your weight. Press the numbers on the keypad or the speed INCREASE or DECREASE keys to select the appropriate weight. The weight will vary from 50 to 400 pounds (23 to 182 kilograms). Press JustGoTM/ENTER key to accept.

4.Select successively the Interval distance, number of repeats, Pace (by entering the required speed in order to choose the closest PACE wanted), Recovery Time and Recovery Pace using on each selection the speed INCREASE or DECREASE keys to select the appropriate value (values permitted are described above). Press JustGoTM/ENTER key to accept each selection.

5.To start the exercise, press the JustGoTM/ENTER key to accept.

WARNING – This is for serious runners only. There is fast acceleration involved…

Gerkin Protocol Program (Required wireless chest strap)

1.The Gerkin Protocol program (based on Gerkin Protocol) is a graded submaximal V02 test used by the International Association of Fire Fighters to determine fitness for fire department duty.

2.The test is a series of 1 minute exercise stages, alternating between elevation grade and speed (i.e. first minute elevation is increased, next minute speed is increased, etc.) until the individual heart rate exceeds the target exercise heart rate.

3.The text ends when the target heart rate is reached and is maintained for 15 seconds. The results are converted in a V02 MAX value that will be shown in the central information window at the end of the test.

4.The target exercise heart rate is 85 percent of the predicted maximal heart rate for a specific individual based on age.

To select the Gerkin Protocol program:

Press the OTHER PROGRAMS key and select the Gerkin Protocol program and follow the instructions shown in the central information window.

21

Image 21
Contents T360 T560 Contents For Your Personal Safety Impotant Safety NoticeKnow Your Heart Rate Electrical InformationResponsibility of the User T360 T560 Limited WarrantyGetting to know the T360 T560 Computer display Monitor T360T360--T5T560Keys Scanning Feature Pausing During an ExerciseSaving an Exercise custom programs Language Feature Access to Settings MenuViewing Exercise Parameters Fitness Networking Cardio Theater, Fit LinxxDistance Unit Feature Weight Unit FeatureWarm Up and Cool Down Feature Heart Rate Control Options Feature Beeper FeatureHeart Rate Access Options Feature User Identification Feature Time, Distance or Calories FeatureTable of minimum and maximum values Activate UserEdit User Reset StatisticsView Statistics Delete UserSpeed Limits Edit Text FeaturePause Time Big Number OptionMax Duration Heart Rate Recovery16 Add/Remove Program Learn ProgramSaving Option On or Off Program LevelsJustGoTM Program Manual Program Cardiovascular ProgramInterval Program Random Program Hill Climb Program Walk ProgramTrack Program Speed Run ProgramRunner’s Interval Program Gerkin Protocol Program Required wireless chest strapHeart Rate Access Feature Requires wireless chest strap Using Contact Heart RateHow to Use Heart Rate Access Memory & Learn ProgramsChanging Your Target Heart Rate in a Program Usingsi a Heart Rate Receiveri rPossible Chest Strap Heart Rate Problems Troubleshooting Check List TablePossible Contact Heart Rate Problems Nvram Test Access to Diagnostics menuEprom test Keypad TestBeeper test Heart Rate TestBelt Alignment Motor Check Safety Key testElevation Calibration StatisticsMaintenance Error logCurrent test Speed Sensor testBelt and Running Deck Running Belt General CareLubricant application Deck SurfaceProblem Possible CAUSE/SOLUTION Quick Troubleshooting Check ListProblem Cause / Solution Error CodesThank You for Purchasing a Bodyguard T360 T560 International Safety requirements North AmericaInterference limits requirements North America CanadaMade in Canada